<?xml version='1.0' encoding='UTF-8'?>
<metadata xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
  <idinfo>
    <citation>
      <citeinfo>
        <origin>Todd, Erin (ORCID: 0000-0002-4871-9730)</origin>
        <origin>Jones, James V. III (ORCID: 0000-0002-6602-5935)</origin>
        <origin>Caine, Jonathan S. (ORCID: 0000-0002-7269-6989)</origin>
        <origin>Kreiner, Douglas C. (ORCID: 0000-0002-4405-1403)</origin>
        <origin>Holm-Denoma, Christopher (ORCID: 0000-0003-3229-5440)</origin>
        <origin>Allard, Andy J. (ORCID: 0000-0001-7426-8382)</origin>
        <origin>Lease, Richard O. (ORCID: 0000-0003-2582-8966)</origin>
        <origin>Case, George N. (ORCID: 0000-0001-9826-5661)</origin>
        <origin>Wypych, Alicja (ORCID: 0000-0001-5406-0445)</origin>
        <pubdate>20220718</pubdate>
        <title>Whole Rock Major and Trace Element Chemistry for Igneous and Metamorphic Rocks from the Yukon-Tanana Upland, Alaska</title>
        <geoform>tabular digital data</geoform>
        <pubinfo>
          <pubplace>Anchorage, Alaska</pubplace>
          <publish>U.S. Geological Survey, Alaska Science Center</publish>
        </pubinfo>
        <othercit>Suggested Citation:  Todd, E., Jones, J.V. III, Caine, J.S., Kreiner, D.C., Holm-Denoma, C., Allard, A.J, Lease, R.O., Case, G.N., Wypych, A., 2022, Whole rock major and trace element chemistry for igneous and metamorphic rocks from the Yukon-Tanana Upland, Alaska: U.S. Geological Survey data release, https://doi.org/10.5066/P9AX4NAE</othercit>
        <onlink>https://doi.org/10.5066/P9AX4NAE</onlink>
      </citeinfo>
    </citation>
    <descript>
      <abstract>This dataset consists of one table containing whole-rock geochemistry data for 753 igneous and metamorphic rocks from the Yukon-Tanana upland of eastern interior Alaska, collected between 2013 and 2019. All materials were analyzed by ALS Global, between 2014 and 2020, by a range of different techniques, so multiple unique entries for a given element relate to different analytical methods or preparations, as detailed in accompanying metadata.</abstract>
      <purpose>This data setwas developed from samples collected during geological mapping and research conducted from 2013 to 2019, including a mix of surficial and drill-core material. The geochemical data from igneous and metamorphic rock samples aid in the interpretation of possible tectonic environment, melting sources, and crystallization history. These data contribute to understanding the geologic history of the Alaska Range.</purpose>
      <supplinf>Sample collection was funded by the Mineral Resources Program of the U.S. Geological Survey. All materials were analyzed by ALS Global between 2014 and 2020.</supplinf>
    </descript>
    <timeperd>
      <timeinfo>
        <rngdates>
          <begdate>2013</begdate>
          <enddate>2020</enddate>
        </rngdates>
      </timeinfo>
      <current>observed</current>
    </timeperd>
    <status>
      <progress>Complete</progress>
      <update>None planned</update>
    </status>
    <spdom>
      <bounding>
        <westbc>-144.90</westbc>
        <eastbc>-139.35</eastbc>
        <northbc>65.20</northbc>
        <southbc>61.55</southbc>
      </bounding>
    </spdom>
    <keywords>
      <theme>
        <themekt>USGS Metadata Identifier</themekt>
        <themekey>USGS:ASC479</themekey>
      </theme>
      <theme>
        <themekt>ISO 19115 Topic Category</themekt>
        <themekey>GeoScientificInformation</themekey>
      </theme>
      <theme>
        <themekt>NASA GCMD Earth Science Keyword Thesaurus</themekt>
        <themekey>Earth science</themekey>
        <themekey>Metamorphic rocks</themekey>
        <themekey>Igneous rocks</themekey>
      </theme>
      <theme>
        <themekt>USGS Thesaurus</themekt>
        <themekey>Geology</themekey>
        <themekey>Geochemistry</themekey>
        <themekey>Isotopic analysis</themekey>
        <themekey>Mass spectroscopy</themekey>
        <themekey>X-ray fluorescence</themekey>
      </theme>
      <theme>
        <themekt>GeoRef Thesaurus</themekt>
        <themekey>Volcaniclastics</themekey>
      </theme>
      <theme>
        <themekt>None</themekt>
        <themekey>Inductively-Coupled-Plasma-Atomic-Emission-Spectroscopy</themekey>
        <themekey>Inductively-Coupled-Plasma-Mass-Spectrometry</themekey>
        <themekey>Trace elements</themekey>
      </theme>
      <place>
        <placekt>USGS Geographic Names Information System (GNIS)</placekt>
        <placekey>Alaska</placekey>
        <placekey>Alaska Range</placekey>
      </place>
      <place>
        <placekt>None</placekt>
        <placekey>Yukon-Tanana</placekey>
      </place>
    </keywords>
    <accconst>No access constraints.</accconst>
    <useconst>No use constraints. These data are marked with a Creative Common CC0 1.0 Universal License and are in the public domain. It is requested that this USGS data release be cited for any subsequent publications that reference or utilize these data. Users are advised to read the dataset's metadata thoroughly to understand appropriate use and data limitations.</useconst>
    <ptcontac>
      <cntinfo>
        <cntorgp>
          <cntorg>U.S. Geological Survey, Alaska Science Center</cntorg>
        </cntorgp>
        <cntaddr>
          <addrtype>Mailing and Physical</addrtype>
          <address>4210 University Drive</address>
          <city>Anchorage</city>
          <state>Alaska</state>
          <postal>99508</postal>
          <country>USA</country>
        </cntaddr>
        <cntvoice>907-786-7000</cntvoice>
        <cntemail>gs-ak_asc_datamanagers@usgs.gov</cntemail>
      </cntinfo>
    </ptcontac>
  </idinfo>
  <dataqual>
    <attracc>
      <attraccr>All laboratories calibrated the analyses to well-characterized standard materials and solutions. See Process Steps for more specific details within the laboratory and reporting environments.</attraccr>
    </attracc>
    <logic>No unexpected values are found in these data, which were reviewed and determined to fall within normal ranges. Blank cells in the data tables indicate values were either not provided, not measured, or not calculated. ALS Labs adjusted lower detection limits of reporting for specific element analyses; this information is noted in the attribute definitions for the analyses limit reporting altered. Data is reported in CSV files; if these files are opened directly in Microsoft Excel, data values may be truncated if they contain trailing zeroes.</logic>
    <complete>This data set is complete; and includes analyses of standard reference materials.</complete>
    <posacc>
      <horizpa>
        <horizpar>Horizontal position for each sample was determined by hand-held GPS units with positional accuracy of 3 meters or less.</horizpar>
      </horizpa>
    </posacc>
    <lineage>
      <srcinfo>
        <srccite>
          <citeinfo>
            <origin>Todd, E.</origin>
            <origin>Wypych, A.</origin>
            <origin>Kylander-Clark, A.R.C.</origin>
            <pubdate>2019</pubdate>
            <title>U-Pb and Lu-Hf isotope, age, and trace element data from zircon separates from the Tanacross D-1, and parts of D-2, C-1, and C-2 quadrangles</title>
            <geoform>tabular digital data, document</geoform>
            <serinfo>
              <sername>Alaska DGGS Raw Data File</sername>
              <issue>2019-5</issue>
            </serinfo>
            <pubinfo>
              <pubplace>online</pubplace>
              <publish>Alaska Division of Geological and Geophysical Surveys (DGGS)</publish>
            </pubinfo>
            <othercit>Todd, E., Wypych, A., Kylander-Clark, A.R.C. 2019. U-Pb and Lu-Hf isotope, age, and trace element data from zircon separates from the Tanacross D-1, and parts of D-2, C-1, and C-2 quadrangles. DGGS Raw Data File 2019-5, 12 p., https://doi.org/10.14509/30198</othercit>
            <onlink>https://doi.org/10.14509/30198</onlink>
          </citeinfo>
        </srccite>
        <typesrc>publication</typesrc>
        <srctime>
          <timeinfo>
            <sngdate>
              <caldate>2019</caldate>
            </sngdate>
          </timeinfo>
          <srccurr>publication date</srccurr>
        </srctime>
        <srccitea>Todd and others, 2019</srccitea>
        <srccontr>Correlation of samples, locality, and ages for igneous rock units.</srccontr>
      </srcinfo>
      <srcinfo>
        <srccite>
          <citeinfo>
            <origin>Holm-Denoma, C.S.</origin>
            <origin>Pianowski, L.S.</origin>
            <origin>Kreiner, D.</origin>
            <pubdate>2022</pubdate>
            <title>U-Pb zircon data for igneous units related to mineralization in the eastern Yukon-Tanana upland, eastern Alaska</title>
            <geoform>tabular digital data</geoform>
            <serinfo>
              <sername>USGS Data Release</sername>
              <issue>doi:10.5066/P9RANVXY</issue>
            </serinfo>
            <pubinfo>
              <pubplace>online</pubplace>
              <publish>U.S. Geological Survey, Alaska Science Center</publish>
            </pubinfo>
            <othercit>Holm-Denoma, C.S., Pianowski, L.S., Kreiner, D. 2022. U-Pb zircon data for igneous units related to mineralization in the eastern Yukon-Tanana upland, eastern Alaska: U.S. Geological Survey Data Release, https://doi.org/10.5066/P9RANVXY</othercit>
            <onlink>https://doi.org/10.5066/P9RANVXY</onlink>
          </citeinfo>
        </srccite>
        <typesrc>digital database file</typesrc>
        <srctime>
          <timeinfo>
            <sngdate>
              <caldate>2022</caldate>
            </sngdate>
          </timeinfo>
          <srccurr>publication date</srccurr>
        </srctime>
        <srccitea>Holm-Denoma et al. 2022</srccitea>
        <srccontr>Sample information correlations</srccontr>
      </srcinfo>
      <srcinfo>
        <srccite>
          <citeinfo>
            <origin>Kreiner, D.C.</origin>
            <origin>Vasquez, J.</origin>
            <pubdate>2022</pubdate>
            <title>Zircon trace element data for igneous units related to mineralization in the eastern Yukon-Tanana upland and nearby areas, eastern Alaska</title>
            <geoform>tabular digital data</geoform>
            <serinfo>
              <sername>USGS Data Release</sername>
              <issue>doi:10.5066/P9Q6GYMH</issue>
            </serinfo>
            <pubinfo>
              <pubplace>online</pubplace>
              <publish>U.S. Geological Survey, Alaska Science Center</publish>
            </pubinfo>
            <othercit>Kreiner, D.C., Vasquez, J. 2022. Zircon trace element data for igneous units related to mineralization in the eastern Yukon-Tanana upland and nearby areas, eastern Alaska: U.S. Geological Survey data release, https://doi.org/10.5066/P9Q6GYMH</othercit>
            <onlink>https://doi.org/10.5066/P9Q6GYMH</onlink>
          </citeinfo>
        </srccite>
        <typesrc>digital database file</typesrc>
        <srctime>
          <timeinfo>
            <sngdate>
              <caldate>2022</caldate>
            </sngdate>
          </timeinfo>
          <srccurr>publication date</srccurr>
        </srctime>
        <srccitea>Kreiner and Vasquez, 2022</srccitea>
        <srccontr>Sample information correlations</srccontr>
      </srcinfo>
      <srcinfo>
        <srccite>
          <citeinfo>
            <origin>Jones, J.V., III</origin>
            <origin>O'Sullivan, P.B.</origin>
            <pubdate>2020</pubdate>
            <title>U-Pb Isotopic Data and Ages of Zircon and Titanite from Rocks from the Yukon-Tanana Upland, Alaska</title>
            <geoform>tabular digital data</geoform>
            <serinfo>
              <sername>USGS Data Release</sername>
              <issue>doi:10.5066/P9WWV93S</issue>
            </serinfo>
            <pubinfo>
              <pubplace>online</pubplace>
              <publish>U.S. Geological Survey, Alaska Science Center</publish>
            </pubinfo>
            <othercit>Jones, J.V., III, O'Sullivan, P.B. 2020. U-Pb Isotopic Data and Ages of Zircon and Titanite from Rocks from the Yukon-Tanana Upland, Alaska: U.S. Geological Survey data release, https://doi.org/10.5066/P9WWV93S</othercit>
            <onlink>https://doi.org/10.5066/P9WWV93S</onlink>
          </citeinfo>
        </srccite>
        <typesrc>digital database file</typesrc>
        <srctime>
          <timeinfo>
            <sngdate>
              <caldate>2020</caldate>
            </sngdate>
          </timeinfo>
          <srccurr>publication date</srccurr>
        </srctime>
        <srccitea>Jones and O'Sullivan, 2020</srccitea>
        <srccontr>Geochronology inputs from samples collected within the region for correlation</srccontr>
      </srcinfo>
      <srcinfo>
        <srccite>
          <citeinfo>
            <origin>Todd, E.</origin>
            <origin>Kylander-Clark, A.R.C.</origin>
            <pubdate>2022</pubdate>
            <title>U-Pb Ages, Hafnium Isotope Ratios, and Trace Element Concentrations by Laser-Ablation Split Stream (LASS) Analysis of Igneous Zircons from the Western Alaska Range</title>
            <geoform>tabular digital data</geoform>
            <serinfo>
              <sername>USGS Data Release</sername>
              <issue>doi:10.5066/P9HE4U9N</issue>
            </serinfo>
            <pubinfo>
              <pubplace>online</pubplace>
              <publish>U.S. Geological Survey, Alaska Science Center</publish>
            </pubinfo>
            <othercit>Todd, E., Kylander-Clark, A. 2022, U-Pb Ages, Hafnium isotope ratios, and trace element concentrations by Laser-Ablation Split Stream (LASS) analysis of igneous zircons from the western Alaska Range: U.S. Geological Survey data release, https://doi.org/10.5066/P9HE4U9N</othercit>
            <onlink>https://doi.org/10.5066/P9HE4U9N</onlink>
          </citeinfo>
        </srccite>
        <typesrc>digital database file</typesrc>
        <srctime>
          <timeinfo>
            <sngdate>
              <caldate>2022</caldate>
            </sngdate>
          </timeinfo>
          <srccurr>publication date</srccurr>
        </srctime>
        <srccitea>Todd and Kylander-Clark, 2022</srccitea>
        <srccontr>Sample information from the region.</srccontr>
      </srcinfo>
      <srcinfo>
        <srccite>
          <citeinfo>
            <origin>Wilson, F.H.</origin>
            <origin>Hults, C.P.</origin>
            <origin>Mull, C.G.</origin>
            <origin>Karl, S.M.</origin>
            <pubdate>2015</pubdate>
            <title>Geologic Map of Alaska</title>
            <geoform>vector digital data, map</geoform>
            <serinfo>
              <sername>USGS Scientific Investigations Map</sername>
              <issue>SIM 3340</issue>
            </serinfo>
            <pubinfo>
              <pubplace>online</pubplace>
              <publish>U.S. Geological Survey, Alaska Science Center</publish>
            </pubinfo>
            <othercit>Wilson, F.H., Hults, C.P., Mull, C.G., Karl, S.M. 2015. Geologic Map of Alaska: USGS Scientific Investigations Map 3340  https://doi.org/10.3133/sim3340</othercit>
            <onlink>https://doi.org/10.3133/sim3340</onlink>
          </citeinfo>
        </srccite>
        <typesrc>digital database file</typesrc>
        <srctime>
          <timeinfo>
            <sngdate>
              <caldate>2015</caldate>
            </sngdate>
          </timeinfo>
          <srccurr>publication date</srccurr>
        </srctime>
        <srccitea>Wilson et al 2015</srccitea>
        <srccontr>Provides geologic unit information used in this data release.</srccontr>
      </srcinfo>
      <procstep>
        <procdesc>Methods used for sample preparation of geochemistry analyses by ALS between 2014 and 2020. Prior to crushing, samples for whole-rock analysis were trimmed by USGS staff to remove weathering or heterogeneities, and cut surfaces were lapped to remove any saw metal. Sample material is crushed to &gt;70% passing 2 mm, and a 250 g split is then pulverized in low-chrome steel grinding mills to &gt;85% passing 75 microns, with barren material passing through pulverizers between each sample. Approximately 3-5g aliquots of USGS standard reference materials (AGV2 - andesite, BHVO2 – basalt, DNC1 - dolerite, DTS2b - dunite, GSP2 - granodiorite, QLO1 - quartz latite, W-2 - diabase), plus two internal standards (12AJJ39E, 12AJJ46A) were submitted as unknown samples to monitor accuracy, and replicates of seven of these (AGV2, BHVO2, DNC1, GSP2, and W2, plus the two internal standards) were run in different sessions to monitor laboratory reproducibility. 'Field_Name' in file "geochemistry_igneousMetamorphic_dataDictionary_yukonTanana_2022_todd.csv" provides element (or element oxide), unit (% versus ppm/ppb), and a subscript composite indicating the analytical method. The method subscript begins with "ME_" and is followed by a method code, which refers to analytical packages, each with varying decomposition and analytical techniques, and are described as subsequent Process Steps.</procdesc>
        <procdate>Unknown</procdate>
      </procstep>
      <procstep>
        <procdesc>"XRF26" – A calcined or ignited sample (0.9 g) is added to 9.0g of lithium borate Flux (50 % - 50 % Li2B4O7 - LiBO2), mixed well and fused in an auto fluxer between 1050 - 1100°C. A flat molten glass disc is prepared from the resulting melt. This disc is then analyzed by X-ray fluorescence (XRF) spectrometry.</procdesc>
        <procdate>Unknown</procdate>
      </procstep>
      <procstep>
        <procdesc>"OA_GRA05x" – The total oxide content is determined from the XRF analyte concentrations and loss on Ignition (L.O.I.) values. A prepared sample (1.0 g) is placed in an oven at 1000°C for one hour, cooled and then weighed. The percent loss on ignition is calculated from the difference in weight.</procdesc>
        <procdate>Unknown</procdate>
      </procstep>
      <procstep>
        <procdesc>"ICP06" – A prepared sample (0.200 g) is added to lithium metaborate/lithium tetraborate (LiBO2 /Li2B4O7) flux (0.90 g), mixed well and fused in a furnace at 1000°C. The resulting melt is then cooled and dissolved in 100 mL of 4% nitric acid/2% hydrochloric acid. This solution is then analyzed by inductively coupled plasma atomic emission spectroscopy (ICP-AES) and the results are corrected for spectral inter-element interferences. Oxide concentration is calculated from the determined elemental concentration and the result is reported in that format.</procdesc>
        <procdate>Unknown</procdate>
      </procstep>
      <procstep>
        <procdesc>"GRA05" - The total oxide content is determined from the ICP analyte concentrations and loss on ignition (L.O.I.) values. A prepared sample (1.0 g) is placed in an oven at 1000°C for one hour, cooled and then weighed. The percent loss on ignition is calculated from the difference in weight.</procdesc>
        <procdate>Unknown</procdate>
      </procstep>
      <procstep>
        <procdesc>"MS81" - A prepared sample (0.200 g) is added to lithium metaborate flux (0.90 g), mixed well, and fused in a furnace at 1000°C. The resulting melt is then cooled and dissolved in 100 mL of 4% HNO3 / 2% HCl3 solution. This solution is then analyzed by inductively coupled plasma - mass spectrometry (ICP-MS).</procdesc>
        <procdate>Unknown</procdate>
      </procstep>
      <procstep>
        <procdesc>"4ACD81" - Prepared sample (0.25 g) is digested by four (perchloric, nitric, hydrofluoric, and hydrochloric) acids, suitable for the determination of base metals since many sulfides and some metal oxides are only partially decomposed by the borate fusion and some elements such as cadmium and zinc can be volatilized. Not suitable for mercury determination (Aqua Regia digest preferred). This solution is then analyzed by ICP-MS.</procdesc>
        <procdate>unknown</procdate>
      </procstep>
      <procstep>
        <procdesc>"MS42" - Prepared sample (0.25 g) is digested with Aqua Regia (nitric and hydrochloric acids), suitable for the determination of most base metals since many sulfides and some metal oxides are only partially decomposed by the borate fusion and some elements such as cadmium and zinc can be volatilized. Not suitable for nickel and cobalt determination (four acid digest preferred). This solution is then analyzed by ICP-MS.</procdesc>
        <procdate>unknown</procdate>
      </procstep>
      <procstep>
        <procdesc>"MS61" – Prepared sample (0.25g) is digested with HNO₃-HClO₄-HF, and an HCl leach, dissolving nearly all minerals in most geological samples. The resulting salt is dissolved in 100 mL of 4% HNO3 / 2% HCl3 solution. This solution is then analyzed by inductively coupled plasma - mass spectrometry (ICP-MS).</procdesc>
        <procdate>unknown</procdate>
      </procstep>
      <procstep>
        <procdesc>"MS61L" - Same as MS61 (Process Step 9), but with improved lower detection limits.</procdesc>
        <procdate>unknown</procdate>
      </procstep>
      <procstep>
        <procdesc>"ICP21" - Au by fire assay and ICP-AES, 30g nominal sample weight.</procdesc>
        <procdate>unknown</procdate>
      </procstep>
      <procstep>
        <procdesc>"MS25NS" - Nickel sulphide collection fire assay and ICP-MS finish. 30g nominal sample weight.</procdesc>
        <procdate>unknown</procdate>
      </procstep>
      <procstep>
        <procdesc>"XRF05" - A finely ground sample powder (10 g minimum) is mixed with a few drops of liquid binder (Polyvinyl Alcohol) and then transferred into an aluminum cap. The sample is subsequently compressed under approximately 30 ton/in^2 in a pellet press. After pressing, the pellet is dried to remove the solvent and analyzed by WDXRF spectrometry.</procdesc>
        <procdate>unknown</procdate>
      </procstep>
      <procstep>
        <procdesc>"OG62" - NI by HF-HNO3-HClO4 digestion (0.4g sample) with HCl leach, ICP-AES finish; run by default when Ni_ppm_ME_MS41 determination is over limit.</procdesc>
        <procdate>unknown</procdate>
      </procstep>
    </lineage>
  </dataqual>
  <spdoinfo>
    <direct>Point</direct>
  </spdoinfo>
  <spref>
    <horizsys>
      <geograph>
        <latres>0.0001</latres>
        <longres>0.0001</longres>
        <geogunit>Decimal degrees</geogunit>
      </geograph>
      <geodetic>
        <horizdn>World Geodetic System of 1984 (WGS84)</horizdn>
        <ellips>World Geodetic System of 1984 (WGS84)</ellips>
        <semiaxis>6378137</semiaxis>
        <denflat>298.257223563</denflat>
      </geodetic>
    </horizsys>
  </spref>
  <eainfo>
    <detailed>
      <enttyp>
        <enttypl>geochemistry_igneousMetamorphic_dataDictionary_yukonTanana_2022_todd.csv</enttypl>
        <enttypd>Table outlining the contents of table "geochemistry_igneousMetamorphicWholeRock_yukonTananaUpland_2022_todd.csv", with field names, descriptions, and upper/lower detection limits for analyses, as applicable. This table contains 132 entries and is presented in comma separated value (.csv) format.</enttypd>
        <enttypds>Author defined</enttypds>
      </enttyp>
      <attr>
        <attrlabl>Field_Name</attrlabl>
        <attrdef>Field name found in data table listed.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <udom>Attributes in this field are single words or concatenated abbreviations that describe the contents of the field.</udom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Field_Explanation</attrlabl>
        <attrdef>Brief description of the contents of 'Field_Name'.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <udom>Attributes in this field are brief descriptions of the contents of 'Field_Name', and include unit of measure, as applicable.</udom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Unit_of_Measure</attrlabl>
        <attrdef>Abbreviations or symbols to indicate units of measure for applicable analyses; 'n/a' when not applicable</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>n/a</edomv>
            <edomvd>n/a = measure units not applicable to this parameter</edomvd>
            <edomvds>Author defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>%</edomv>
            <edomvd>% = weight percent</edomvd>
            <edomvds>Author defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>kg</edomv>
            <edomvd>kg = kilograms</edomvd>
            <edomvds>Author defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>ppb</edomv>
            <edomvd>ppb = parts per billion</edomvd>
            <edomvds>Author defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>ppm</edomv>
            <edomvd>ppm = parts per million</edomvd>
            <edomvds>Author defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Lower_Detection_Limit</attrlabl>
        <attrdef>Minimum detection and reporting parameters for the analytical method as listed in 'Field_Explanation'.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <udom>The attributes in this data set are a number and a unit of measure (wt pct, ppb, or ppm), or "n/a" when reporting limits do not apply.</udom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Upper_Detection_Limit</attrlabl>
        <attrdef>Maximum detection and reporting parameters for the analytical method as listed in 'Field_Explanation'.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <udom>The attributes in this data set are a number and a unit of measure (wt pct, ppb, or ppm), or "n/a" when reporting limits do not apply.</udom>
        </attrdomv>
      </attr>
    </detailed>
    <detailed>
      <enttyp>
        <enttypl>geochemistry_igneousMetamorphicWholeRock_yukonTananaUpland_2022_todd.csv</enttypl>
        <enttypd>Table with sample information, including location, rock descriptions, and various geochemical analysis for multiple elements, including trace element concentration data. This table contains 790 entries and is presented in comma separated value (.csv) format.</enttypd>
        <enttypds>Author defined</enttypds>
      </enttyp>
      <attr>
        <attrlabl>Index</attrlabl>
        <attrdef>Numeric identifier used for sorting purposes within this table only.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>1</rdommin>
            <rdommax>790</rdommax>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Sample</attrlabl>
        <attrdef>Sample number as collected in the field or established standard identifier; this is either a USGS or laboratory specific alphanumeric identifier.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <udom>Sample identifier; most labels consist of the last two digits of the year collected, an abbreviation identifying the sample collector, and a number and possible suffix. Sample identifiers for established standard reference materials are also noted; these may be repeated over multiple analyses as a check for accuracy and reference for laboratory reproducibility. Core sample names generally include a one or two letter code for site, the last 2 digits of the year drilled, and down-hole core depth interval, although formatting and depth units vary from site to site. All are presented here as originally recorded, without units used, for consistency with other occurrences of these materials in other sources.</udom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Report</attrlabl>
        <attrdef>Geochemistry report number, generated by analytical contractor; First two digits following the letters 'FA' refer to last two digits of calendar year of analysis.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <udom>Values listed here are identifiers created by the analytical contractor that contain alphanumeric sequences denoting a specific report of analysis completed within a calendar year.</udom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Unit</attrlabl>
        <attrdef>Tentative geological map unit inferred for each sample, using the simplified map units from Wilson et al. (2015). These unit designations are provided for informational purposes only, to aid in the interpretation of these data. In some cases, sample units are inconsistent with map unit at their location. In these instances, the unit designation is based on a combination of the field interpretations made by individual researchers during new mapping and collection of these samples, and the availability of new UPb ages (Todd et al., 2019; Jones and O'Sullivan, 2020; Todd and Kylander-Clark, 2022; Holm-Denoma et al., 2022). Units listed here are the Map unit labels from Wilson et al. (2015), with some exceptions. First, we do not make a distinction between KJgu and Kmgr, presuming all samples within either are mid-Cretaceous, and are all labeled here as Kmgr. Second, new unit codes are added here, one each for Permain and early Tertiary plutons (Pmg, Tp, respectively). Neither Permian nor a locally appropriate Tertiary plutonic units are described in the referenced map, and the only local early Tertiary unit is volcanic (Tv). And third, several plutonic igneous samples included here are located with unit TKpr, a mapped late-Cretaceous pyroclastic unit in Wilson et al. (2015), so we apply the less-common TKgi (intrusive) unit label to these.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <udom>Values listed here are alphanumeric designators indicating geologic age and lithology abbreviations. This field does not contain unique values, as several samples may be grouped together within a geologic unit designator for more broad source analysis.</udom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Longitude</attrlabl>
        <attrdef>Sample location longitude in decimal degrees, datum WGS84.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-144.8914</rdommin>
            <rdommax>-139.3644</rdommax>
            <attrunit>Decimal degrees (WGS84)</attrunit>
            <attrmres>0.0001</attrmres>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Latitude</attrlabl>
        <attrdef>Sample location latitude in decimal degrees, datum WGS84.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>61.5693</rdommin>
            <rdommax>65.1865</rdommax>
            <attrunit>Decimal degrees (WGS84)</attrunit>
            <attrmres>0.0001</attrmres>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Type</attrlabl>
        <attrdef>Designation of material being analyzed, whether sample or standard material.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>Sample</edomv>
            <edomvd>Sample material collected in the field as part of the study.</edomvd>
            <edomvds>Author defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>Standard</edomv>
            <edomvd>Material designated and maintained specifically for laboratory reproducibility and accuracy.</edomvd>
            <edomvds>Author defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Rock_Class</attrlabl>
        <attrdef>Primary rock classification (e.g. igneous, metamorphic, meta-igneous, or vein). Empty cells are present, indicating either a laboratory standard reference material sample or an undefined rock sample.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>Igneous</edomv>
            <edomvd>Primary rock classification = Igneous</edomvd>
            <edomvds>Author defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>Igneous-Meta</edomv>
            <edomvd>Primary rock classification = Metamorphosed Igneous</edomvd>
            <edomvds>Author defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>Metamorphic</edomv>
            <edomvd>Primary rock classification = Metamorphic</edomvd>
            <edomvds>Author defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>Vein</edomv>
            <edomvd>Primary rock classification = Vein</edomvd>
            <edomvds>Author defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Rock_Type</attrlabl>
        <attrdef>Igneous or metamorphic subtype. Empty cells are present, indicating either a laboratory standard reference material sample or that the sample was not further classified by the collector.</attrdef>
        <attrdefs>Producer Defined</attrdefs>
        <attrdomv>
          <udom>Where Rock_Class is "Igneous," attribute indicates whether plutonic or volcanic/volcaniclastic, plus a "(meta)" designation if metamorphosed igneous. Where Rock_Class is "Metamorphic," attribute indicates grade or protolith type, if available.</udom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Rock_Name</attrlabl>
        <attrdef>Rock name, as described in original collector field notes. Empty cells indicate the sample was a noted standard for laboratory control or not classified into a further subclass by the collector.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <udom>Values included in this field are further visual and general geologic and chemical categorizations of rock. This is a free text field.</udom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Description</attrlabl>
        <attrdef>Sample rock description, from original collector field notes. This is a free text field, and may contain abbreviations or shorthand observations that are offered as supplemental information only. Blank cells may be present, indicating no notes or additional information was available.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <udom>Values included here are generally verbiage from the sample collector's field notes. This is a free text field.</udom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Rcvd_Sample_Wt_kg</attrlabl>
        <attrdef>Sample weight received by processing laboratory, in kilograms.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.02</rdommin>
            <rdommax>1.95</rdommax>
            <attrunit>kilograms (kg)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>SiO2_%_ME_XRF26</attrlabl>
        <attrdef>Silicon, as silicon dioxide (SiO2) in weight percent; measured by X-Ray fluorescence spectroscopy (XRF). A null or empty cell means not analyzed.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>40.9</rdommin>
            <rdommax>77.2</rdommax>
            <attrunit>weight percent (wt %)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>TiO2_%_ME_XRF26</attrlabl>
        <attrdef>Titanium, as titanium dioxide (TiO2) in weight percent; measured by X-Ray fluorescence spectroscopy (XRF). A null or empty cell means not analyzed.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.01</rdommin>
            <rdommax>3.22</rdommax>
            <attrunit>weight percent (wt %)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Al2O3_%_ME_XRF26</attrlabl>
        <attrdef>Aluminum, as aluminum trioxide (Al2O3) in weight percent; measured by X-Ray fluorescence spectroscopy (XRF). A null or empty cell means not analyzed.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>1.04</rdommin>
            <rdommax>19.65</rdommax>
            <attrunit>weight percent (wt %)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Fe2O3_%_ME_XRF26</attrlabl>
        <attrdef>Iron, as iron trioxide (Fe2O3) in weight percent; measured by X-Ray fluorescence spectroscopy (XRF). A null or empty cell means not analyzed.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.74</rdommin>
            <rdommax>15.78</rdommax>
            <attrunit>weight percent (wt %)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>MnO_%_ME_XRF26</attrlabl>
        <attrdef>Manganese, as manganese oxide (MnO) in weight percent; measured by X-Ray fluorescence spectroscopy (XRF). A null or empty cell means not analyzed.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.01</rdommin>
            <rdommax>0.27</rdommax>
            <attrunit>weight percent (wt %)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>MgO_%_ME_XRF26</attrlabl>
        <attrdef>Magnesium, as magnesium oxide (MgO) in weight percent; measured by X-Ray fluorescence spectroscopy (XRF). A null or empty cell means not analyzed.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.03</rdommin>
            <rdommax>40.50</rdommax>
            <attrunit>weight percent (wt %)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>CaO_%_ME_XRF26</attrlabl>
        <attrdef>Calcium, as calcium oxide (CaO) in weight percent; measured by X-Ray fluorescence spectroscopy (XRF). A null or empty cell means not analyzed.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.02</rdommin>
            <rdommax>16.25</rdommax>
            <attrunit>weight percent (wt %)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Na2O_%_ME_XRF26</attrlabl>
        <attrdef>Sodium, as sodium oxide (Na2O) in weight percent; measured by X-Ray fluorescence spectroscopy (XRF). A null or empty cell means not analyzed.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.14</rdommin>
            <rdommax>5.66</rdommax>
            <attrunit>weight percent (wt %)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>K2O_%_ME_XRF26</attrlabl>
        <attrdef>Potassium, as potassium oxide (K2O) in weight percent; measured by X-Ray fluorescence spectroscopy (XRF). A null or empty cell means not analyzed. A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-0.01</rdommin>
            <rdommax>8.06</rdommax>
            <attrunit>weight percent (wt %)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>P2O5_%_ME_XRF26</attrlabl>
        <attrdef>Phosphorus, as phosphorus pentoxide (P2O5) in weight percent; measured by X-Ray fluorescence spectroscopy (XRF). A null or empty cell means not analyzed. A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-0.01</rdommin>
            <rdommax>0.66</rdommax>
            <attrunit>weight percent (wt %)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>BaO_%_ME_XRF26</attrlabl>
        <attrdef>Barium, as barium oxide (BaO) in weight percent; measured by X-Ray fluorescence spectroscopy (XRF). A null or empty cell means not analyzed.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.02</rdommin>
            <rdommax>0.39</rdommax>
            <attrunit>weight percent (wt %)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Cr2O3_%_ME_XRF26</attrlabl>
        <attrdef>Chromium, as chromium dioxide (Cr2O3) in weight percent; measured by X-Ray fluorescence spectroscopy (XRF). A null or empty cell means not analyzed.  A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-0.01</rdommin>
            <rdommax>0.39</rdommax>
            <attrunit>weight percent (wt %)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>SrO_%_ME_XRF26</attrlabl>
        <attrdef>Strontium, as strontium dioxide (SrO) in weight percent; measured by X-Ray fluorescence spectroscopy (XRF). A null or empty cell means not analyzed. A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-0.01</rdommin>
            <rdommax>0.15</rdommax>
            <attrunit>weight percent (wt %)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>LOI_%_OA_GRA05x</attrlabl>
        <attrdef>Loss on ignition, in weight percent, at 1000°C (accompanying XRF analyses). A null or empty cell means not analyzed.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.09</rdommin>
            <rdommax>11.98</rdommax>
            <attrunit>weight percent (wt %)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Total_%_ME_XRF26</attrlabl>
        <attrdef>Raw sum of oxide weight percent total by XRF (not the sum of oxides here). A null or empty cell means not analyzed.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>98.77</rdommin>
            <rdommax>100.95</rdommax>
            <attrunit>weight percent (wt %)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>SiO2_%_ME_ICP06</attrlabl>
        <attrdef>Silicon, as silicon dioxide (SiO2) in weight percent; measured by inductively coupled plasma atomic emission spectroscopy (ICP-AES). A null or empty cell means not analyzed.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>4.39</rdommin>
            <rdommax>94.60</rdommax>
            <attrunit>weight percent (wt %)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>TiO2_%_ME_ICP06</attrlabl>
        <attrdef>Titanium, as titanium dioxide (TiO2) in weight percent; measured by inductively coupled plasma atomic emission spectroscopy (ICP-AES). A null or empty cell means not analyzed. A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-0.01</rdommin>
            <rdommax>4.06</rdommax>
            <attrunit>weight percent (wt %)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Al2O3_%_ME_ICP06</attrlabl>
        <attrdef>Aluminum, as aluminum trioxide (Al2O3) in weight percent; measured by inductively coupled plasma atomic emission spectroscopy (ICP-AES). A null or empty cell means not analyzed.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.21</rdommin>
            <rdommax>26.00</rdommax>
            <attrunit>weight percent (wt %)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Fe2O3_%_ME_ICP06</attrlabl>
        <attrdef>Iron, as iron trioxide (Fe2O3) in weight percent; measured by inductively coupled plasma atomic emission spectroscopy (ICP-AES). A null or empty cell means not analyzed.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.40</rdommin>
            <rdommax>42.10</rdommax>
            <attrunit>weight percent (wt %)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>MnO_%_ME_ICP06</attrlabl>
        <attrdef>Manganese, as manganese oxide (MnO) in weight percent; measured by inductively coupled plasma atomic emission spectroscopy (ICP-AES). A null or empty cell means not analyzed. A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-0.01</rdommin>
            <rdommax>1.53</rdommax>
            <attrunit>weight percent (wt %)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>MgO_%_ME_ICP06</attrlabl>
        <attrdef>Magnesium, as magnesium oxide (MgO) in weight percent; measured by inductively coupled plasma atomic emission spectroscopy (ICP-AES). A null or empty cell means not analyzed. A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-0.01</rdommin>
            <rdommax>48.50</rdommax>
            <attrunit>weight percent (wt %)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>CaO_%_ME_ICP06</attrlabl>
        <attrdef>Calcium, as calcium oxide (CaO) in weight percent; measured by inductively coupled plasma atomic emission spectroscopy (ICP-AES). A null or empty cell means not analyzed.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.01</rdommin>
            <rdommax>34.00</rdommax>
            <attrunit>weight percent (wt %)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Na2O_%_ME_ICP06</attrlabl>
        <attrdef>Sodium, as sodium oxide (Na2O) in weight percent; measured by inductively coupled plasma atomic emission spectroscopy (ICP-AES). A null or empty cell means not analyzed. A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-0.01</rdommin>
            <rdommax>7.25</rdommax>
            <attrunit>weight percent (wt %)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>K2O_%_ME_ICP06</attrlabl>
        <attrdef>Potassium, as potassium oxide (K2O) in weight percent; measured by inductively coupled plasma atomic emission spectroscopy (ICP-AES). A null or empty cell means not analyzed. A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-0.01</rdommin>
            <rdommax>8.50</rdommax>
            <attrunit>weight percent (wt %)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>P2O5_%_ME_ICP06</attrlabl>
        <attrdef>Phosphorus, as phosphorus pentoxide (P2O5) in weight percent; measured by inductively coupled plasma atomic emission spectroscopy (ICP-AES). A null or empty cell means not analyzed.  A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-0.01</rdommin>
            <rdommax>1.82</rdommax>
            <attrunit>weight percent (wt %)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>BaO_%_ME_ICP06</attrlabl>
        <attrdef>Barium, as barium oxide (BaO) in weight percent; measured by inductively coupled plasma atomic emission spectroscopy (ICP-AES). A null or empty cell means not analyzed.  A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-0.01</rdommin>
            <rdommax>0.88</rdommax>
            <attrunit>weight percent (wt %)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Cr2O3_%_ME_ICP06</attrlabl>
        <attrdef>Chromium, as chromium dioxide (Cr2O3) in weight percent; measured by inductively coupled plasma atomic emission spectroscopy (ICP-AES). A null or empty cell means not analyzed. Lower detection limit reporting was changed from 0.01 to 0.002 by ALS Labs in 2018. A value of -0.01 or -0.002 represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-0.002</rdommin>
            <rdommax>2.36</rdommax>
            <attrunit>weight percent (wt %)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>SrO_%_ME_ICP06</attrlabl>
        <attrdef>Strontium, as strontium dioxide (SrO) in weight percent; measured by inductively coupled plasma atomic emission spectroscopy (ICP-AES). A null or empty cell means not analyzed.  A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-0.01</rdommin>
            <rdommax>0.23</rdommax>
            <attrunit>weight percent (wt %)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>LOI_%_OA_GRA05</attrlabl>
        <attrdef>Loss on ignition, in weight percent, at 1000°C (accompanying ICP-AES analyses). A null or empty cell means not analyzed.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-0.64</rdommin>
            <rdommax>41.20</rdommax>
            <attrunit>weight percent (wt %)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Total_%_TOT_ICP06</attrlabl>
        <attrdef>Raw sum of oxide weight percent total by ICP-AES (not the sum of oxides here). A null or empty cell means not analyzed.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>47.78</rdommin>
            <rdommax>102.00</rdommax>
            <attrunit>weight percent (wt %)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>FeO_Fe_VOL</attrlabl>
        <attrdef>Iron concentration as determined by titration. A null or empty cell means not analyzed.</attrdef>
        <attrdefs>Author Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.39</rdommin>
            <rdommax>10.75</rdommax>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>S_%_S_IR</attrlabl>
        <attrdef>Sulfur (S) concentration, in weight percent, of total sulphur; determined by induction furnace/infrared analysis. A null or empty cell means not analyzed.  A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-0.01</rdommin>
            <rdommax>5.55</rdommax>
            <attrunit>weight percent (wt %)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>C_%_C_IR</attrlabl>
        <attrdef>Carbon (C) concentration, in weight percent, of total carbon; determined by induction furnace/infrared analysis. A null or empty cell means not analyzed.  A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-0.01</rdommin>
            <rdommax>11.10</rdommax>
            <attrunit>weight percent (wt %)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Ba_ppm_ME_MS81</attrlabl>
        <attrdef>Barium (Ba) in parts per million; measured by inductively coupled plasma mass spectrometry (ICP-MS). A null or empty cell means not analyzed. Note that lower detection limits for this analysis were changed by ALS Labs in 2018 from 0.5 to 0.1.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>1.4</rdommin>
            <rdommax>8230.0</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Ce_ppm_ME_MS81</attrlabl>
        <attrdef>Cerium (Ce) in parts per million; measured by inductively coupled plasma mass spectrometry (ICP-MS). A null or empty cell means not analyzed. A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-0.5</rdommin>
            <rdommax>471.0</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Cr_ppm_ME_MS81</attrlabl>
        <attrdef>Chromium (Cr) in parts per million; measured by inductively coupled plasma mass spectrometry (ICP-MS). A null or empty cell means not analyzed.  A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute. A value of 10000.1111 means that detection limit of the instrument was exceeded.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-10</rdommin>
            <rdommax>10000.1111</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Cs_ppm_ME_MS81</attrlabl>
        <attrdef>Cesium (Cs) in parts per million; measured by inductively coupled plasma mass spectrometry (ICP-MS). A null or empty cell means not analyzed. A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-0.01</rdommin>
            <rdommax>178.05</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Dy_ppm_ME_MS81</attrlabl>
        <attrdef>Dysprosium (Dy) in parts per million; measured by inductively coupled plasma mass spectrometry (ICP-MS). A null or empty cell means not analyzed. A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-0.05</rdommin>
            <rdommax>34.1</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Er_ppm_ME_MS81</attrlabl>
        <attrdef>Erbium (Er) in parts per million; measured by inductively coupled plasma mass spectrometry (ICP-MS). A null or empty cell means not analyzed. A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-0.03</rdommin>
            <rdommax>23.70</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Eu_ppm_ME_MS81</attrlabl>
        <attrdef>Europium (Eu) in parts per million; measured by inductively coupled plasma mass spectrometry (ICP-MS). A null or empty cell means not analyzed. Lower detection limit reporting was changed from 0.03 to 0.02 by ALS Labs in 2020. A value of -0.02 or -0.03 represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-0.03</rdommin>
            <rdommax>8.75</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Ga_ppm_ME_MS81</attrlabl>
        <attrdef>Gallium (Ga) in parts per million; measured by inductively coupled plasma mass spectrometry (ICP-MS). A null or empty cell means not analyzed.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.6</rdommin>
            <rdommax>47.3</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Gd_ppm_ME_MS81</attrlabl>
        <attrdef>Gadolinium (Gd) in parts per million; measured by inductively coupled plasma mass spectrometry (ICP-MS). A null or empty cell means not analyzed. A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-0.05</rdommin>
            <rdommax>36.20</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Ge_ppm_ME_MS81</attrlabl>
        <attrdef>Germanium (Ge) in parts per million; measured by inductively coupled plasma mass spectrometry (ICP-MS). A null or empty cell means not analyzed.  A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-5</rdommin>
            <rdommax>5</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Hf_ppm_ME_MS81</attrlabl>
        <attrdef>Hafnium (Hf) in parts per million; measured by inductively coupled plasma mass spectrometry (ICP-MS). A null or empty cell means not analyzed. Lower detection limit reporting was changed from 0.2 to 0.1 by ALS Labs in 2020. A value of -0.1 or -0.2 represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-0.2</rdommin>
            <rdommax>30.0</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Ho_ppm_ME_MS81</attrlabl>
        <attrdef>Holmium (Ho) in parts per million; measured by inductively coupled plasma mass spectrometry (ICP-MS). A null or empty cell means not analyzed. A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-0.01</rdommin>
            <rdommax>7.89</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>La_ppm_ME_MS81</attrlabl>
        <attrdef>Lanthanum (La) in parts per million; measured by inductively coupled plasma mass spectrometry (ICP-MS). A null or empty cell means not analyzed. Lower detection limit reporting was changed from 0.5 to 0.01 by ALS Labs in 2018. A value of -0.5 or -0.1 represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-0.5</rdommin>
            <rdommax>207.0</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Lu_ppm_ME_MS81</attrlabl>
        <attrdef>Lutetium (Lu) in parts per million; measured by inductively coupled plasma mass spectrometry (ICP-MS). A null or empty cell means not analyzed. A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-0.01</rdommin>
            <rdommax>4.01</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Nb_ppm_ME_MS81</attrlabl>
        <attrdef>Niobium (Nb) in parts per million; measured by inductively coupled plasma mass spectrometry (ICP-MS). A null or empty cell means not analyzed. Lower detection limit reporting was changed from 0.2 to 0.1 by ALS Labs in 2020. A value of -0.2 or -0.1 represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-0.2</rdommin>
            <rdommax>370.0</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Nd_ppm_ME_MS81</attrlabl>
        <attrdef>Neodymium (Nd) in parts per million; measured by inductively coupled plasma mass spectrometry (ICP-MS). A null or empty cell means not analyzed. A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-0.1</rdommin>
            <rdommax>219.0</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Pr_ppm_ME_MS81</attrlabl>
        <attrdef>Praseodymium (Pr) in parts per million; measured by inductively coupled plasma mass spectrometry (ICP-MS). A null or empty cell means not analyzed. Lower detection limit reporting was changed from 0.03 to 0.02 by ALS Labs in 2020. A value of -0.02 or -0.03 represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-0.03</rdommin>
            <rdommax>59.7</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Rb_ppm_ME_MS81</attrlabl>
        <attrdef>Rubidium (Rb) in parts per million; measured by inductively coupled plasma mass spectrometry (ICP-MS). A null or empty cell means not analyzed. A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-0.2</rdommin>
            <rdommax>710.0</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Sm_ppm_ME_MS81</attrlabl>
        <attrdef>Samarium (Sm) in parts per million; measured by inductively coupled plasma mass spectrometry (ICP-MS). A null or empty cell means not analyzed. A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-0.03</rdommin>
            <rdommax>33.30</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Sn_ppm_ME_MS81</attrlabl>
        <attrdef>Tin (Sn) in parts per million; measured by inductively coupled plasma mass spectrometry (ICP-MS). A null or empty cell means not analyzed.  A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-1</rdommin>
            <rdommax>78</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Sr_ppm_ME_MS81</attrlabl>
        <attrdef>Strontium (Sr) in parts per million; measured by inductively coupled plasma mass spectrometry (ICP-MS). A null or empty cell means not analyzed.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.7</rdommin>
            <rdommax>2010.0</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Ta_ppm_ME_MS81</attrlabl>
        <attrdef>Tantalum (Ta) in parts per million; measured by inductively coupled plasma mass spectrometry (ICP-MS). A null or empty cell means not analyzed.  A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-0.1</rdommin>
            <rdommax>19.3</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Tb_ppm_ME_MS81</attrlabl>
        <attrdef>Terbium (Tb) in parts per million; measured by inductively coupled plasma mass spectrometry (ICP-MS). A null or empty cell means not analyzed. A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-0.01</rdommin>
            <rdommax>5.45</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Th_ppm_ME_MS81</attrlabl>
        <attrdef>Thorium (Th) in parts per million; measured by inductively coupled plasma mass spectrometry (ICP-MS). A null or empty cell means not analyzed. A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-0.05</rdommin>
            <rdommax>113.00</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Tm_ppm_ME_MS81</attrlabl>
        <attrdef>Thulium (Tm) in parts per million; measured by inductively coupled plasma mass spectrometry (ICP-MS). A null or empty cell means not analyzed. A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-0.01</rdommin>
            <rdommax>3.62</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>U_ppm_ME_MS81</attrlabl>
        <attrdef>Uranium (U) in parts per million; measured by inductively coupled plasma mass spectrometry (ICP-MS). A null or empty cell means not analyzed. A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-0.05</rdommin>
            <rdommax>40.70</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>V_ppm_ME_MS81</attrlabl>
        <attrdef>Vanadium (V) in parts per million; measured by inductively coupled plasma mass spectrometry (ICP-MS). A null or empty cell means not analyzed.  A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-5</rdommin>
            <rdommax>2600</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>W_ppm_ME_MS81</attrlabl>
        <attrdef>Tungsten (W) in parts per million; measured by inductively coupled plasma mass spectrometry (ICP-MS). A null or empty cell means not analyzed.  A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-1</rdommin>
            <rdommax>78</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Y_ppm_ME_MS81</attrlabl>
        <attrdef>Yttrium (Y) in parts per million; measured by inductively coupled plasma mass spectrometry (ICP-MS). A null or empty cell means not analyzed. Lower detection limit reporting was changed from 0.5 to 0.1 by ALS Labs in 2018. A value of -0.5 or -0.1 represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-0.5</rdommin>
            <rdommax>228.0</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Yb_ppm_ME_MS81</attrlabl>
        <attrdef>Ytterbium (Yb) in parts per million; measured by inductively coupled plasma mass spectrometry (ICP-MS). A null or empty cell means not analyzed. A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-0.03</rdommin>
            <rdommax>25.40</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Zr_ppm_ME_MS81</attrlabl>
        <attrdef>Zirconium (Zr) in parts per million; measured by inductively coupled plasma mass spectrometry (ICP-MS). A null or empty cell means not analyzed.  A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-2</rdommin>
            <rdommax>1250</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Ag_ppm_ME_4ACD81</attrlabl>
        <attrdef>Silver (Ag) in parts per million; measured by inductively coupled plasma mass spectrometry (ICP-MS). A null or empty cell means not analyzed.  A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute. A value of 100.1111 means the measurement exceeded parameters detectable by the instrument.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-0.5</rdommin>
            <rdommax>100.1111</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>As_ppm_ME_4ACD81</attrlabl>
        <attrdef>Arsenic (As) in parts per million; measured by inductively coupled plasma mass spectrometry (ICP-MS). A null or empty cell means not analyzed.  A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-5</rdommin>
            <rdommax>45</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Cd_ppm_ME_4ACD81</attrlabl>
        <attrdef>Cadmium (Cd) in parts per million; measured by inductively coupled plasma mass spectrometry (ICP-MS). A null or empty cell means not analyzed. A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute. A value of 1000.1111 means the measurement exceeded parameters detectable by the instrument.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-0.5</rdommin>
            <rdommax>1000.1111</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Co_ppm_ME_4ACD81</attrlabl>
        <attrdef>Cobalt (Co) in parts per million; measured by inductively coupled plasma mass spectrometry (ICP-MS). A null or empty cell means not analyzed.  A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-1</rdommin>
            <rdommax>158</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Cu_ppm_ME_4ACD81</attrlabl>
        <attrdef>Copper (Cu) in parts per million; measured by inductively coupled plasma mass spectrometry (ICP-MS). A null or empty cell means not analyzed.  A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-1</rdommin>
            <rdommax>3440</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Li_ppm_ME_4ACD81</attrlabl>
        <attrdef>Lithium (Li) in parts per million; measured by inductively coupled plasma mass spectrometry (ICP-MS). A null or empty cell means not analyzed.  A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-10</rdommin>
            <rdommax>180</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Mo_ppm_ME_4ACD81</attrlabl>
        <attrdef>Molybdenum (Mo) in parts per million; measured by inductively coupled plasma mass spectrometry (ICP-MS). A null or empty cell means not analyzed.  A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-1</rdommin>
            <rdommax>525</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Ni_ppm_ME_4ACD81</attrlabl>
        <attrdef>Nickel (Ni) in parts per million; measured by inductively coupled plasma mass spectrometry (ICP-MS). A null or empty cell means not analyzed.  A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-1</rdommin>
            <rdommax>4040</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Pb_ppm_ME_4ACD81</attrlabl>
        <attrdef>Lead (Pb) in parts per million; measured by inductively coupled plasma mass spectrometry (ICP-MS). A null or empty cell means not analyzed.  A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute. A value of 10000.1111 means the measurement exceeded parameters detectable by the instrument.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-2</rdommin>
            <rdommax>10000.1111</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Sc_ppm_ME_4ACD81</attrlabl>
        <attrdef>Scandium (Sc) in parts per million; measured by inductively coupled plasma mass spectrometry (ICP-MS). A null or empty cell means not analyzed.  A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-1</rdommin>
            <rdommax>77</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Tl_ppm_ME_4ACD81</attrlabl>
        <attrdef>Thallium (Tl) in parts per million; measured by inductively coupled plasma mass spectrometry (ICP-MS). A null or empty cell means not analyzed.  A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-10.0</rdommin>
            <rdommax>10.0</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Zn_ppm_ME_4ACD81</attrlabl>
        <attrdef>Zinc (Zn) in parts per million; measured by inductively coupled plasma mass spectrometry (ICP-MS). A null or empty cell means not analyzed. A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute. A value of 10000.1111 means the measurement exceeded parameters detectable by the instrument.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-2</rdommin>
            <rdommax>10000.1111</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>As_ppm_ME_MS42</attrlabl>
        <attrdef>Arsenic (As) in parts per million; measured by inductively coupled plasma mass spectrometry (ICP-MS). A null or empty cell means not analyzed.  A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute. A value of 250.1111 means the measurement exceeded parameters detectable by the instrument.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-0.1</rdommin>
            <rdommax>250.1111</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Bi_ppm_ME_MS42</attrlabl>
        <attrdef>Bismuth (Bi) in parts per million; measured by inductively coupled plasma mass spectrometry (ICP-MS). A null or empty cell means not analyzed.  A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-0.01</rdommin>
            <rdommax>74.00</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Hg_ppm_ME_MS42</attrlabl>
        <attrdef>Mercury (Hg) in parts per million; measured by inductively coupled plasma mass spectrometry (ICP-MS). A null or empty cell means not analyzed.  A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-0.005</rdommin>
            <rdommax>1.215</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>In_ppm_ME_MS42</attrlabl>
        <attrdef>Indium (In) in parts per million; measured by inductively coupled plasma mass spectrometry (ICP-MS). A null or empty cell means not analyzed.  A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-0.005</rdommin>
            <rdommax>1.505</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Re_ppm_ME_MS42</attrlabl>
        <attrdef>Rhenium (Re) in parts per million; measured by inductively coupled plasma mass spectrometry (ICP-MS). A null or empty cell means not analyzed.  A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-0.001</rdommin>
            <rdommax>0.839</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Sb_ppm_ME_MS42</attrlabl>
        <attrdef>Antimony (Sb) in parts per million; measured by inductively coupled plasma mass spectrometry (ICP-MS). A null or empty cell means not analyzed. A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute. A value of 250.1111 means the measurement exceeded parameters detectable by the instrument.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-0.05</rdommin>
            <rdommax>250.1111</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Sc_ppm_ME_MS42</attrlabl>
        <attrdef>Scandium (Sc) in parts per million; measured by inductively coupled plasma mass spectrometry (ICP-MS). A null or empty cell means not analyzed.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.2</rdommin>
            <rdommax>19.00</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Se_ppm_ME_MS42</attrlabl>
        <attrdef>Selenium (Se) in parts per million; measured by inductively coupled plasma mass spectrometry (ICP-MS). A null or empty cell means not analyzed.  A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-0.2</rdommin>
            <rdommax>8.9</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Te_ppm_ME_MS42</attrlabl>
        <attrdef>Tellurium (Te) in parts per million; measured by inductively coupled plasma mass spectrometry (ICP-MS). A null or empty cell means not analyzed.  A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-0.01</rdommin>
            <rdommax>4.23</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Tl_ppm_ME_MS42</attrlabl>
        <attrdef>Thallium (Tl) in parts per million; measured by inductively coupled plasma mass spectrometry (ICP-MS). A null or empty cell means not analyzed.  A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-0.02</rdommin>
            <rdommax>3.49</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Ag_ppm_ME_MS61</attrlabl>
        <attrdef>Silver (Ag) in parts per million, measured by inductively coupled plasma - mass spectrometry (ICP-MS). A null or empty cell means not analyzed.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.01</rdommin>
            <rdommax>0.06</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Cd_ppm_ME_MS61</attrlabl>
        <attrdef>Cadmium (Cd) in parts per million, measured by inductively coupled plasma - mass spectrometry (ICP-MS). A null or empty cell means not analyzed. A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-0.02</rdommin>
            <rdommax>0.20</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Co_ppm_ME_MS61</attrlabl>
        <attrdef>Cobalt (Co) in parts per million, measured by inductively coupled plasma - mass spectrometry (ICP-MS). A null or empty cell means not analyzed.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>37.5</rdommin>
            <rdommax>127.0</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Cu_ppm_ME_MS61</attrlabl>
        <attrdef>Copper (Cu) in parts per million, measured by inductively coupled plasma - mass spectrometry (ICP-MS). A null or empty cell means not analyzed.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>4.3</rdommin>
            <rdommax>130.5</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Li_ppm_ME_MS61</attrlabl>
        <attrdef>Lithium (Li) in parts per million, measured by inductively coupled plasma - mass spectrometry (ICP-MS). A null or empty cell means not analyzed.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.4</rdommin>
            <rdommax>23.4</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Mo_ppm_ME_MS61</attrlabl>
        <attrdef>Molybdenum (Mo) in parts per million, measured by inductively coupled plasma - mass spectrometry (ICP-MS). A null or empty cell means not analyzed.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.09</rdommin>
            <rdommax>3.42</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Ni_ppm_ME_MS61</attrlabl>
        <attrdef>Nickel (Ni) in parts per million, measured by inductively coupled plasma - mass spectrometry (ICP-MS). A null or empty cell means not analyzed.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>32</rdommin>
            <rdommax>3640</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Pb_ppm_ME_MS61</attrlabl>
        <attrdef>Lead (Pb) in parts per million, measured by inductively coupled plasma - mass spectrometry (ICP-MS). A null or empty cell means not analyzed. A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-0.5</rdommin>
            <rdommax>4.9</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Sc_ppm_ME_MS61</attrlabl>
        <attrdef>Scandium (Sc) in parts per million, measured by inductively coupled plasma - mass spectrometry (ICP-MS). A null or empty cell means not analyzed.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>2.8</rdommin>
            <rdommax>74.3</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Ag_ppm_ME_MS61L</attrlabl>
        <attrdef>Silver (Ag) in parts per million, measured by inductively coupled plasma - mass spectrometry (ICP-MS). A null or empty cell means not analyzed.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.005</rdommin>
            <rdommax>36.300</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Cd_ppm_ME_MS61L</attrlabl>
        <attrdef>Cadmium (Cd) in parts per million, measured by inductively coupled plasma - mass spectrometry (ICP-MS). A null or empty cell means not analyzed. A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-0.005</rdommin>
            <rdommax>8.8600</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Co_ppm_ME_MS61L</attrlabl>
        <attrdef>Cobalt (Co) in parts per million, measured by inductively coupled plasma - mass spectrometry (ICP-MS). A null or empty cell means not analyzed.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.16</rdommin>
            <rdommax>68.70</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Cu_ppm_ME_MS61L</attrlabl>
        <attrdef>Copper (Cu) in parts per million, measured by inductively coupled plasma - mass spectrometry (ICP-MS). A null or empty cell means not analyzed.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.57</rdommin>
            <rdommax>2130.00</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Li_ppm_ME_MS61L</attrlabl>
        <attrdef>Lithium (Li) in parts per million, measured by inductively coupled plasma - mass spectrometry (ICP-MS). A null or empty cell means not analyzed.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>2</rdommin>
            <rdommax>223</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Mo_ppm_ME_MS61L</attrlabl>
        <attrdef>Molybdenum (Mo) in parts per million, measured by inductively coupled plasma - mass spectrometry (ICP-MS). A null or empty cell means not analyzed.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.15</rdommin>
            <rdommax>193.50</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Ni_ppm_ME_MS61L</attrlabl>
        <attrdef>Nickel (Ni) in parts per million, measured by inductively coupled plasma - mass spectrometry (ICP-MS). A null or empty cell means not analyzed.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.52</rdommin>
            <rdommax>246.00</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Pb_ppm_ME_MS61L</attrlabl>
        <attrdef>Lead (Pb) in parts per million, measured by inductively coupled plasma - mass spectrometry (ICP-MS). A null or empty cell means not analyzed.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.53</rdommin>
            <rdommax>3980.00</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Sc_ppm_ME_MS61L</attrlabl>
        <attrdef>Scandium (Sc) in parts per million, measured by inductively coupled plasma - mass spectrometry (ICP-MS). A null or empty cell means not analyzed.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.60</rdommin>
            <rdommax>81.20</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Zn_ppm_ME_MS61L</attrlabl>
        <attrdef>Zinc (Zn) in parts per million, measured by inductively coupled plasma - mass spectrometry (ICP-MS). A null or empty cell means not analyzed.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>1.5</rdommin>
            <rdommax>1220.0</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Au_ppm_Au_ICP21</attrlabl>
        <attrdef>Gold (Au) concentration in parts per million, measured after fire assay by inductively coupled plasma - atomic emission spectrometry (ICP-AES). A null or empty cell means not analyzed. A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-0.001</rdommin>
            <rdommax>0.001</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Pt_ppb_PGM_MS25NS</attrlabl>
        <attrdef>Platinum (Pt) concentration in parts per billion, measured after nickel sulfide assay by inductively coupled plasma - mass spectrometry (ICP-MS). A null or empty cell means not analyzed. A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-2</rdommin>
            <rdommax>5</rdommax>
            <attrunit>parts per billion (ppb)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Pd_ppb_PGM_MS25NS</attrlabl>
        <attrdef>Palladium (Pd) concentration in parts per billion, measured after nickel sulfide assay by inductively coupled plasma - mass spectrometry (ICP-MS). A null or empty cell means not analyzed. A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-2</rdommin>
            <rdommax>5</rdommax>
            <attrunit>parts per billion (ppb)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Au_ppb_PGM_MS25NS</attrlabl>
        <attrdef>Gold (Au) concentration in parts per billion, measured after nickel sulfide assay by inductively coupled plasma - mass spectrometry (ICP-MS). A null or empty cell means not analyzed. A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-2</rdommin>
            <rdommax>-2</rdommax>
            <attrunit>parts per billion (ppb)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Rh_ppb_PGM_MS25NS</attrlabl>
        <attrdef>Rhodium (Rh) concentration in parts per billion, measured after nickel sulfide assay by inductively coupled plasma - mass spectrometry (ICP-MS). A null or empty cell means not analyzed. A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-2</rdommin>
            <rdommax>-2</rdommax>
            <attrunit>parts per billion (ppb)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Ir_ppb_PGM_MS25NS</attrlabl>
        <attrdef>Iridium (Ir) concentration in parts per billion, measured after nickel sulfide assay by inductively coupled plasma - mass spectrometry (ICP-MS). A null or empty cell means not analyzed. A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-1</rdommin>
            <rdommax>3</rdommax>
            <attrunit>parts per billion (ppb)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Os_ppb_PGM_MS25NS</attrlabl>
        <attrdef>Osmium (Os) concentration in parts per billion, measured after nickel sulfide assay by inductively coupled plasma - mass spectrometry (ICP-MS). A null or empty cell means not analyzed. A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-2</rdommin>
            <rdommax>4</rdommax>
            <attrunit>parts per billion (ppb)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Ru_ppb_PGM_MS25NS</attrlabl>
        <attrdef>Ruthenium (Ru) concentration in parts per billion, measured after nickel sulfide assay by inductively coupled plasma - mass spectrometry (ICP-MS). A null or empty cell means not analyzed. A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-3</rdommin>
            <rdommax>6</rdommax>
            <attrunit>parts per billion (ppb)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Nb_ppm_ME_XRF05</attrlabl>
        <attrdef>Niobium (Nb) in parts per million; measured by X-Ray fluorescence spectroscopy (XRF). A null or empty cell means not analyzed.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-2.00</rdommin>
            <rdommax>22.00</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Y_ppm_ME_XRF05</attrlabl>
        <attrdef>Yttrium (Y) in parts per million; measured by X-Ray fluorescence spectroscopy (XRF). A null or empty cell means not analyzed. A null or empty cell means not analyzed. A negative value represents the analysis is below the detection limit, which is the absolute value of the attribute.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-2</rdommin>
            <rdommax>52</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Zr_ppm_ME_XRF05</attrlabl>
        <attrdef>Zirconium (Zr) in parts per million; measured by X-Ray fluorescence spectroscopy (XRF). A null or empty cell means not analyzed.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-2</rdommin>
            <rdommax>312</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Ag_ppm_Ag_OG62</attrlabl>
        <attrdef>Silver (Ag) in parts per million; measured by inductively coupled plasma atomic emission spectroscopy (ICP-AES). A null or empty cell means not analyzed.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>465</rdommin>
            <rdommax>465</rdommax>
            <attrunit>parts per million (ppm)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Pb_%_Pb_OG62</attrlabl>
        <attrdef>Lead (Pb) in weight percent; measured by inductively coupled plasma atomic emission spectroscopy (ICP-AES). A null or empty cell means not analyzed. A value of 20.1111 represents the measurement exceeded the upper detection limit of the instrument.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>20.1111</rdommin>
            <rdommax>20.1111</rdommax>
            <attrunit>weight percent (wt %)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Zn_%_Zn_OG62</attrlabl>
        <attrdef>Zinc (Zn) in weight percent; measured by inductively coupled plasma atomic emission spectroscopy (ICP-AES). A null or empty cell means not analyzed.</attrdef>
        <attrdefs>Author defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>16.2</rdommin>
            <rdommax>16.2</rdommax>
            <attrunit>weight percent (wt %)</attrunit>
          </rdom>
        </attrdomv>
      </attr>
    </detailed>
  </eainfo>
  <distinfo>
    <distrib>
      <cntinfo>
        <cntorgp>
          <cntorg>U.S. Geological Survey</cntorg>
          <cntper>USGS ScienceBase Team</cntper>
        </cntorgp>
        <cntaddr>
          <addrtype>Mailing and Physical</addrtype>
          <address>Denver Federal Center, Building 810, Mail Stop 302</address>
          <city>Denver</city>
          <state>Colorado</state>
          <postal>80225</postal>
          <country>USA</country>
        </cntaddr>
        <cntvoice>1-888-275-8747</cntvoice>
        <cntemail>sciencebase@usgs.gov</cntemail>
      </cntinfo>
    </distrib>
    <resdesc>The U.S. Geological Survey, Alaska Science Center is the authoritative source of these data, distributed by ScienceBase (a USGS Trusted Digital Repository).</resdesc>
    <distliab>Unless otherwise stated, all data, metadata and related materials are considered to satisfy the quality standards relative to the purpose for which the data were collected. Although these data and associated metadata have been reviewed for accuracy and completeness and approved for release by the U.S. Geological Survey, no warranty expressed or implied is made regarding the display or utility of the data for other purposes or on all computer systems, nor shall the act of distribution constitute any such warranty. Any use of trade, firm, or product names is for descriptive purposes only and does not imply endorsement by the U.S. Government.</distliab>
    <stdorder>
      <digform>
        <digtinfo>
          <formname>CSV, PDF</formname>
          <formcont>Tabular data in CSV format; supplemental documentation in PDF format; FGDC metadata in XML and HTML formats.</formcont>
        </digtinfo>
        <digtopt>
          <onlinopt>
            <computer>
              <networka>
                <networkr>https://doi.org/10.5066/P9AX4NAE</networkr>
              </networka>
            </computer>
          </onlinopt>
        </digtopt>
      </digform>
      <fees>None</fees>
    </stdorder>
  </distinfo>
  <metainfo>
    <metd>20250529</metd>
    <metc>
      <cntinfo>
        <cntorgp>
          <cntorg>U.S. Geological Survey, Alaska Science Center</cntorg>
        </cntorgp>
        <cntaddr>
          <addrtype>Mailing and Physical</addrtype>
          <address>4210 University Drive</address>
          <city>Anchorage</city>
          <state>Alaska</state>
          <postal>99508</postal>
          <country>USA</country>
        </cntaddr>
        <cntvoice>907-786-7000</cntvoice>
        <cntemail>gs-ak_asc_datamanagers@usgs.gov</cntemail>
      </cntinfo>
    </metc>
    <metstdn>FGDC Content Standard for Digital Geospatial Metadata (CSDGM)</metstdn>
    <metstdv>FGDC-STD-001-1998</metstdv>
  </metainfo>
</metadata>
