<?xml version='1.0' encoding='UTF-8'?>
<metadata xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
  <idinfo>
    <citation>
      <citeinfo>
        <origin>Sindy M. Mejia</origin>
        <origin>Emily H. Majcher</origin>
        <origin>Lee Blaney (UMBC)</origin>
        <origin>Ke He (UMBC)</origin>
        <origin>Andrew W. Psoras</origin>
        <origin>Trevor P. Needham</origin>
        <origin>Ellie P. Foss</origin>
        <pubdate>20250314</pubdate>
        <title>Per-and polyfluoroalkyl substances and polychlorinated biphenyls in influent, effluent, and biosolids samples collected from municipal wastewater treatment plants of the Patapsco and Potomac watersheds, 2021-2023</title>
        <geoform>tabular digital data</geoform>
        <onlink>https://doi.org/10.5066/P13WUBAD</onlink>
      </citeinfo>
    </citation>
    <descript>
      <abstract>This metadata record consists of 3 tables containing per-and-poly-fluoroalkyl substances (PFAS) and polychlorinated biphenyls (PCB) concentration data of wastewater and biosolid samples from wastewater treatment plants within the Patapsco and Potomac watersheds. The PCB concentration data was used to assess the occurrence and fate of PCB in wastewater treatment plants within the Patapsco watershed, from December 2021 to December 2022; The PFAS concentration data was used to assess the occurrence and fate of PFAS within the Patapsco and Potomac watersheds, from 2021-2023. The PFAS total oxidizable precursors (TOP) assay data were used to investigate PFAS fate in the wastewater treatment process of plants within the Patapsco watershed from March and September of 2022.</abstract>
      <purpose>These data were collected to assess the status and occurrence, and magnitude of PCB and PFAS in wastewater and biosolid samples of multiple wastewater treatment plants with varying characteristics within the Patapsco and Potomac watersheds. Appropriate use of the data includes assessment of PCB and PFAS in wastewater and biosolids relative to various wastewater plants characteristics.</purpose>
    </descript>
    <timeperd>
      <timeinfo>
        <rngdates>
          <begdate>20211220</begdate>
          <enddate>20230323</enddate>
        </rngdates>
      </timeinfo>
      <current>observed</current>
    </timeperd>
    <status>
      <progress>Complete</progress>
      <update>None planned</update>
    </status>
    <spdom>
      <descgeog>Pennsylvania, Maryland, Virginia, Washington D.C., and West Virginia</descgeog>
      <bounding>
        <westbc>-79.2664</westbc>
        <eastbc>-76.3879</eastbc>
        <northbc>39.8592</northbc>
        <southbc>37.9052</southbc>
      </bounding>
    </spdom>
    <keywords>
      <theme>
        <themekt>ISO 19115 Topic Category</themekt>
        <themekey>environment</themekey>
        <themekey>geoscientificInformation</themekey>
        <themekey>inlandWaters</themekey>
      </theme>
      <theme>
        <themekt>USGS Thesaurus</themekt>
        <themekey>PFAS</themekey>
        <themekey>PCB</themekey>
        <themekey>Wastewater</themekey>
        <themekey>Biosolids</themekey>
        <themekey>Water Quality</themekey>
        <themekey>Water Quality</themekey>
      </theme>
      <theme>
        <themekt>Common geographic areas</themekt>
        <themekey>Maryland</themekey>
        <themekey>Virginia</themekey>
        <themekey>Pennsylvania</themekey>
        <themekey>Washington D.C.</themekey>
      </theme>
      <theme>
        <themekt>Marine Realms Information Bank (MRIB) keywords</themekt>
        <themekey>Chesapeake Bay</themekey>
        <themekey>Patapsco watershed</themekey>
        <themekey>Patapsco River</themekey>
        <themekey>Potomac watershed</themekey>
        <themekey>Potomac River</themekey>
      </theme>
      <theme>
        <themekt>USGS Metadata Identifier</themekt>
        <themekey>USGS:6634f0d3d34ee921b712b8f4</themekey>
      </theme>
    </keywords>
    <accconst>None.  Please see 'Distribution Info' for details.</accconst>
    <useconst>None.  Users are advised to read the dataset's metadata thoroughly to understand appropriate use and data limitations.</useconst>
    <ptcontac>
      <cntinfo>
        <cntorgp>
          <cntorg>U.S. Geological Survey, Northeast Region</cntorg>
          <cntper>Sindy M. Mejia</cntper>
        </cntorgp>
        <cntpos>Physical Scientist</cntpos>
        <cntaddr>
          <addrtype>mailing and physical</addrtype>
          <address>5522 Research Park Drive</address>
          <city>Baltimore</city>
          <state>Maryland</state>
          <postal>21228</postal>
          <country>US</country>
        </cntaddr>
        <cntvoice>410-925-8098</cntvoice>
        <cntemail>smejia@usgs.gov</cntemail>
      </cntinfo>
    </ptcontac>
    <datacred>Data collection was made possible through funding provided by the Urban Waters Federal Partnership Cooperative matching program and the USGS Ecosystem Mission Area. The data included in this release were collected and analyzed by the USGS and the University of Maryland Baltimore County (UMBC) PFAS research laboratory (Catonsville, Maryland).</datacred>
    <native>The PFAS dataset was produced using Microsoft Excel 365 v2308, in a Windows 10 Enterprise v22H2 environment. This file is 53.1 kilobytes and is in comma delimited (.csv) format.
The PCB dataset was produced using Microsoft Excel 365 v2308, in a Windows 10 Enterprise v22H2 environment. This file is 52.9 kilobytes and is in comma delimited (.csv) format.
The PFAS TOP dataset was produced using Microsoft Excel 365 v2308, in a Windows 10 Enterprise v22H2 environment. This file is 7.53 kilobytes and is in comma delimited (.csv) format.</native>
  </idinfo>
  <dataqual>
    <attracc>
      <attraccr>Quality assurance (QA)/quality control (QC) procedures were completed by the USGS and reporting laboratories and are summarized here. Clean hands/ dirty hands (CH/DH) methodology was used to reduce contamination risk during sampling. Both members of the sampling team wore nitrile gloves covered with elbow length polyethylene gloves to handle sample bottles and caps. DH only handled sampler and equipment and did not contact the sample or its container. CH handled only the sample bottles and caps.</attraccr>
    </attracc>
    <logic>Field replicate samples were collected at random from 20% of all Patapsco watershed wastewater treatment plant sites during quarterly sampling events for each sample type (influent, effluent, and biosolids). Blanks were collected each quarter which included equipment and daily trip blanks for aqueous and solid samples.                

Field replicate samples were collected at random from 20% of all Potomac watershed wastewater treatment plant sites for each sample type (influent, effluent, and biosolids). Trip blanks were collected for each sampling day for aqueous and solid samples. Equipment blanks were collected for each sampling event for the same types of samples.                                                                                                             
Equipment blanks were collected by passing 18 M-Ohm deionized water and PFAS free sand over the sampling equipment in the field. Trip blanks were prepared by adding 18 M-Ohm deionized water and PFAS and PCB free sand to sampling containers utilized.                                                                                                                         

PCB data qualifiers &amp; definitions	
H: Relevant calibration check recovery &gt; 130%; Value may be biased high.
L: Relevant calibration check recovery &lt; 70%; Value may be biased low.
U: Measured value below calibration limit; Value represents lower LOQ for specific sample.
E: Measured value above calibration limit; Estimated value.
B: Detection in trip/method/equipment blank; Value may be affected by contamination.
N: Limitations in passive sampler calibration/equilibration; Value not reported.
R: Results for this compound are rejected due to serious deficiencies in the ability to analyze the sample and meet quality-control criteria; Presence or absence cannot be verified.
S: Surrogate recovery &lt; 70%; Value may be biased low.
-: Qualifier does not apply; Reported value is the concentration.                                                                                                                                                                                                                 

PFAS and PFAS TOP data qualifiers &amp; definitions	
U: Associated concentration is less than the LOD and reported as the LOD.
J: Associated concentration is less than the LOQ; The analyte was positively identified, and the concentrations was estimated as the LOQ divided by 2.
B: Compound present in lab, trip, or equipment blank; Blank is above the LOD.</logic>
    <complete>The data include treatment descriptions for sample collection, receipt and analysis for PCB and PFAS.</complete>
    <posacc>
      <horizpa>
        <horizpar>A horizontal accuracy test was not performed for this dataset.</horizpar>
      </horizpa>
      <vertacc>
        <vertaccr>A vertical accuracy test was not performed for this dataset.</vertaccr>
      </vertacc>
    </posacc>
    <lineage>
      <procstep>
        <procdesc>Aqueous and Biosolids Collection: USGS personnel used the CH/DH methodology for collection of samples at all wastewater treatment plants. For aqueous samples, the uncapped HDPE bottle was secured into the metal weighted sampler and lowered into the influent or effluent water stream. The secured uncapped bottle was submerged below the surface twice for rinsing and retrieved once filled to the shoulder level of the bottle, capped, double bagged and put on ice. Overfilled bottles were dumped and re-sampled until desired level was accomplished.                                                                                                                                                                  
Biosolids samples were collected by hand and placed in their respective containers, HDPE centrifuge tubes for PFAS analysis and glass jars for PCB analysis.                                                                                                                         
Polyethylene (PE) passive samplers were used to sample effluent wastewater at the Patapsco watershed wastewater treatment plants. The PE passive samplers were placed within a stainless-steel mesh frame. Samplers were placed in the effluent water flow and remained deployed for 3 months at each location. Upon retrieval the PE passive sampler sheets were removed from the frame, wiped clean using deionized water and Kim wipes and stored in glass vials for transport on ice.                                                                                                                                                                        
All aqueous samples were placed in a -18 degrees Celsius freezer upon arrival to the laboratory and later transferred to a -80 degrees Celsius freezer for storage until they were analyzed. PE passive samplers were kept in a -18 degrees Celsius freezer before analysis. Biosolid samples were later freeze dried in preparation for analysis.</procdesc>
        <procdate>20230325</procdate>
      </procstep>
      <procstep>
        <procdesc>PCB Analysis: All PCB analyses were performed and reported by the USGS MD-DE-DC Water Science Center Analytical Laboratory using gas chromatography-mass spectrometry (GC-MS), an electron capture detector according to U.S. EPA publication SW-846 Method 8082A with a modification based on Mullin (1994). Laboratory analytical methods for extractions and cleanup of biosolids and effluent samples were performed as described in the referenced scientific investigations report (Majcher and others, 2022). 

U.S. EPA. 2007. "Method 8082A(SW-846): Polychlorinated Biphenyls (PCB) by Gas Chromatography, part of Test Methods for Evaluating Solid Waste, Physical/Chemical Methods." Washington, DC. https://www.epa.gov/sites/default/files/2015-12/documents/8082a.pdf

Mullin, M. PCB Congener Quantification for Lake Michigan Mass Balance Study. EPA National Health and Environmental Effects Research Laboratory, Grosse Ille, MI, 1994.

Majcher, E., Ghosh, U., Needham, T.P., Lombard, N., Foss, E.P., Bokare, M., Joshee, S., Cheung, L., Damond, J., and Lorah, M., 2022, Refining Sources of Polychlorinated Biphenyls in the Back River watershed, Baltimore, Maryland, 2018-2020: U.S. Geological Survey Scientific Investigations Report, https://pubs.usgs.gov/sir/2022/5012/sir20225012.pdf</procdesc>
        <procdate>20230125</procdate>
      </procstep>
      <procstep>
        <procdesc>PFAS and PFAS TOP Analysis: PFAS analysis and PFAS by total oxidizable precursors assay were performed by the UMBC PFAS research laboratory by liquid chromatography with triple quadruple tandem mass spectrometry (LC-MS/MS). Quantitative analysis was performed following the procedure described by Blaney and He (2021).

Blaney, L., and He, K. (2021, December 1). Appendix B: Standard Operating Procedures; B1. Scope and Applications (pp. 28-59). Ion Exchange Membranes and Fibers as Passive Samplers for Chemically diverse PFAS. Defense Technical Information Center. https://apps.dtic.mil/sti/citations/trecms/AD1187024</procdesc>
        <procdate>20220615</procdate>
      </procstep>
    </lineage>
  </dataqual>
  <spdoinfo>
    <direct>Vector</direct>
    <ptvctinf>
      <sdtsterm>
        <sdtstype>Entity point</sdtstype>
        <ptvctcnt>62</ptvctcnt>
      </sdtsterm>
    </ptvctinf>
  </spdoinfo>
  <spref>
    <horizsys>
      <geograph>
        <latres>.0197513196</latres>
        <longres>.0254118316</longres>
        <geogunit>Decimal seconds</geogunit>
      </geograph>
      <geodetic>
        <horizdn>North American Datum of 1983 (NAD 83)</horizdn>
        <ellips>Geodetic Reference System 1980</ellips>
        <semiaxis>6378137.000000</semiaxis>
        <denflat>298.257222</denflat>
      </geodetic>
    </horizsys>
  </spref>
  <eainfo>
    <detailed>
      <enttyp>
        <enttypl>PatapscoWWTP_PCBs_Data.csv</enttypl>
        <enttypd>Comma Separated Value (CSV) file containing PCB concentrations from biosolid samples and polyethylene passive samplers captured effluent samples of wastewater treatment plants within the Patapsco watershed in Maryland from March through December 2022.</enttypd>
        <enttypds>USGS Defined</enttypds>
      </enttyp>
      <attr>
        <attrlabl>Sample_ID</attrlabl>
        <attrdef>USGS generated unique sample identifier.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <udom>Each sample was given a unique sequential number by the USGS that corresponds with the sample name for each specific site.</udom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Sample_Name</attrlabl>
        <attrdef>Origin of wastewater or biosolid sample.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <udom>Each site was given a unique name identifier.</udom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Collection_Date</attrlabl>
        <attrdef>Date when the sample was collected from the site.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>3/21/2022</rdommin>
            <rdommax>12/21/2022</rdommax>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Watershed</attrlabl>
        <attrdef>Watershed in which the site is located.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>Patapsco</edomv>
            <edomvd>Affected watershed</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Sample_Type</attrlabl>
        <attrdef>Sample source type</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>Biosolids</edomv>
            <edomvd>Dewatered and treated solid residuals of the wastewater treatment plant.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>Trip Blank BS</edomv>
            <edomvd>Clean sand sample collected in the laboratory.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>Equipment Blank BS</edomv>
            <edomvd>Clean sand sample collected in the field.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>Effluent</edomv>
            <edomvd>Water discharged into a waterway after the wastewater treatment process.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Concentration_Units</attrlabl>
        <attrdef>PCB concentration units are in nanograms per gram of dry weight for biosolid (BS) samples and nanograms per liter for aqueous (AQ) samples.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <udom>PCB concentration units are in nanograms per gram of dry weight for solid samples and nanograms per liter for aqueous samples.</udom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_1_Conc</attrlabl>
        <attrdef>PCB congener 1; 2-Chlorobiphenyl concentration expressed in nanograms per gram of dry weight or in nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.271246</rdommin>
            <rdommax>16.739984</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_1_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congener 1; 2-Chlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>R</edomv>
            <edomvd>Results for this compound are rejected due to serious deficiencies in the ability to analyze the sample and meet quality-control criteria; Presence or absence cannot be verified.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_3_Conc</attrlabl>
        <attrdef>PCB congener 3; 4-Chlorobiphenyl concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.084724</rdommin>
            <rdommax>19.667465</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_3_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congener 3; 4-Chlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>R</edomv>
            <edomvd>Results for this compound are rejected due to serious deficiencies in the ability to analyze the sample and meet quality-control criteria; Presence or absence cannot be verified.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_4_10_Conc</attrlabl>
        <attrdef>PCB congeners 4 and 10; 2,2'-Dichlorobiphenyl and 2,6-Dichlorobiphenyl combined concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.052364</rdommin>
            <rdommax>34.160555</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_4_10_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congeners 4 and 10; 2,2'-Dichlorobiphenyl and 2,6-Dichlorobiphenyl. 
Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>E</edomv>
            <edomvd>Measured value above calibration limit; Estimated value.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>H</edomv>
            <edomvd>Relevant calibration check recovery &gt; 130%; Value may be biased high.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>UH</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample; Relevant calibration check recovery &gt; 130%; Value may be biased high. Relevant calibration check recovery &gt; 130%; Value may be biased high.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>EH</edomv>
            <edomvd>Measured value above calibration limit; Estimated value.
Relevant calibration check recovery &gt; 130%; Value may be biased high.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_7_9_Conc</attrlabl>
        <attrdef>PCB congeners 7 and 9; 2,4-Dichlorobiphenyl and 2,5-Dichlorobiphenyl combined concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.005171</rdommin>
            <rdommax>0.804973</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_7_9_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congeners 7 and 9; 2,4-Dichlorobiphenyl and 2,5-Dichlorobiphenyl. 
Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_6_Conc</attrlabl>
        <attrdef>PCB congener 6; 2,3'-Dichlorobiphenyl concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.008733</rdommin>
            <rdommax>0.714752</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_6_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congener 6; 2,3'-Dichlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>E</edomv>
            <edomvd>Measured value above calibration limit; Estimated value.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_8_5_Conc</attrlabl>
        <attrdef>PCB congeners 8 and 5; 2,4'-Dichlorobiphenyl and 2,3-Dichlorobiphenyl combined concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.061959</rdommin>
            <rdommax>23.533061</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_8_5_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congeners 8 and 5; 2,4'-Dichlorobiphenyl and 2,3-Dichlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_19_Conc</attrlabl>
        <attrdef>PCB congener 19;2,2',6-Trichlorobiphenyl concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.002114</rdommin>
            <rdommax>0.444055</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_19_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congener 19;2,2',6-Trichlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>E</edomv>
            <edomvd>Measured value above calibration limit; Estimated value.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>B</edomv>
            <edomvd>Detection in trip/method/equipment blank; Value may be affected by contamination.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_12_13_Conc</attrlabl>
        <attrdef>PCB congeners 12 and 13; 3,4-Dichlorobiphenyl and 3,4'-Dichlorobiphenyl combined concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.000970</rdommin>
            <rdommax>2.415317</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_12_13_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congeners 12 and 13; 3,4-Dichlorobiphenyl and 3,4'-Dichlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>E</edomv>
            <edomvd>Measured value above calibration limit; Estimated value.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>B</edomv>
            <edomvd>Detection in trip/method/equipment blank; Value may be affected by contamination.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_18_Conc</attrlabl>
        <attrdef>PCB congener 18; 2,2',5-Trichlorobiphenyl concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.01018</rdommin>
            <rdommax>1.842972</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_18_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congener 18; 2,2',5-Trichlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_17_15_Conc</attrlabl>
        <attrdef>PCB congeners 17 and 15; 2,2',4-Trichlorobiphenyl and 4,4'-Dichlorobiphenyl combined concentration expressed in nanograms per gram of dry weight or nanograms per liter or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.008814</rdommin>
            <rdommax>0.626136</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_17_15_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congeners 17 and 15; 2,2',4-Trichlorobiphenyl and 4,4'-Dichlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_24_27_Conc</attrlabl>
        <attrdef>PCB congeners 24 and 27; 2,3,6-Trichlorobiphenyl and 2,3',6-Trichlorobiphenyl combined concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Value not reported.</edomvd>
            <edomvds>USGS defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <rdom>
            <rdommin>0.033454</rdommin>
            <rdommax>0.043931</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_24_27_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congeners 24 and 27; 2,3,6-Trichlorobiphenyl and 2,3',6-Trichlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>N</edomv>
            <edomvd>Limitations in passive sampler calibration/equilibration; Value not reported.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_16_32_Conc</attrlabl>
        <attrdef>PCB congeners 16 and 32; 2,2',3-Trichlorobiphenyl and 2,4',6-Trichlorobiphenyl combined concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.01316</rdommin>
            <rdommax>2.481488</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_16_32_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congeners 16 and 32; 2,2',3-Trichlorobiphenyl and 2,4',6-Trichlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_26_Conc</attrlabl>
        <attrdef>PCB congener 26; 2,3',5-Trichlorobiphenyl concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.001398</rdommin>
            <rdommax>5.169795</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_26_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congener 26; 2,3',5-Trichlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>E</edomv>
            <edomvd>Measured value above calibration limit; Estimated value.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_25_Conc</attrlabl>
        <attrdef>PCB congener 25; 2,3',4-Trichlorobiphenyl concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.000255</rdommin>
            <rdommax>0.246407</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_25_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congener 25; 2,3',4-Trichlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>B</edomv>
            <edomvd>Detection in trip/method/equipment blank; Value may be affected by contamination.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>E</edomv>
            <edomvd>Measured value above calibration limit; Estimated value.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_31_Conc</attrlabl>
        <attrdef>PCB congener 31; 2,4',5-Trichlorobiphenyl concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.004526</rdommin>
            <rdommax>8.25393</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_31_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congener 31; 2,4',5-Trichlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>E</edomv>
            <edomvd>Measured value above calibration limit; Estimated value.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_28_Conc</attrlabl>
        <attrdef>PCB congener 28; 2,4,4'-Trichlorobiphenyl concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.003642</rdommin>
            <rdommax>4.082863</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_28_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congener 28; 2,4,4'-Trichlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_21_33_53_Conc</attrlabl>
        <attrdef>PCB congeners 21, 33 and 53; 2,3,4-Trichlorobiphenyl, 2,3',4'-Trichlorobiphenyl and 2,2',5,6'-Tetrachlorobiphenyl combined concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.004419</rdommin>
            <rdommax>7.312932</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_21_33_53_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congeners 21, 33 and 53; 2,3,4-Trichlorobiphenyl, 2,3',4'-Trichlorobiphenyl and 2,2',5,6'-Tetrachlorobiphenyl. 
Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_51_Conc</attrlabl>
        <attrdef>PCB congener 51; 2,2',4,6'-Tetrachlorobiphenyl concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.000262</rdommin>
            <rdommax>1.812324</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_51_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congener 51; 2,2',4,6'-Tetrachlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>E</edomv>
            <edomvd>Measured value above calibration limit; Estimated value.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>ES</edomv>
            <edomvd>Measured value above calibration limit; Estimated value. Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>US</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample; Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>EB</edomv>
            <edomvd>Measured value above calibration limit; Estimated value.
Detection in trip/method/equipment blank; Value may be affected by contamination.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_22_Conc</attrlabl>
        <attrdef>PCB congener 22; 2,3,4'-Trichlorobiphenyl concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.003189</rdommin>
            <rdommax>1.148041</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_22_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congener 22; 2,3,4'-Trichlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>E</edomv>
            <edomvd>Measured value above calibration limit; Estimated value.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_45_Conc</attrlabl>
        <attrdef>PCB congener 45; 2,2',3,6-Tetrachlorobiphenyl concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.001085</rdommin>
            <rdommax>0.89314</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_45_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congener 45; 2,2',3,6-Tetrachlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>US</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample; Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_46_Conc</attrlabl>
        <attrdef>PCB congener 46; 2,2',3,6'-Tetrachlorobiphenyl concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Value not reported.</edomvd>
            <edomvds>USGS defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <rdom>
            <rdommin>0.050488</rdommin>
            <rdommax>0.321942</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_46_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congener 46; 2,2',3,6'-Tetrachlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>US</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample. Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>N</edomv>
            <edomvd>Limitations in passive sampler calibration/equilibration; Value not reported.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_52_43_Conc</attrlabl>
        <attrdef>PCB congeners 52 and 43; 2,2',5,5'-Tetrachlorobiphenyl and 2,2',3,5-Tetrachlorobiphenyl combined concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.002469</rdommin>
            <rdommax>5.101565</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_52_43_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congeners 52 and 43; 2,2',5,5'-Tetrachlorobiphenyl and 2,2',3,5-Tetrachlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>S</edomv>
            <edomvd>Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>US</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample. Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_49_Conc</attrlabl>
        <attrdef>PCB congener 49; 2,2',4,5'-Tetrachlorobiphenyl concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.001212</rdommin>
            <rdommax>9.610363</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_49_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congener 49; 2,2',4,5'-Tetrachlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>S</edomv>
            <edomvd>Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>US</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample. Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>E</edomv>
            <edomvd>Measured value above calibration limit; Estimated value.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_47_Conc</attrlabl>
        <attrdef>PCB congener 47; 2,2',4,4'-Tetrachlorobiphenyl concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.000526</rdommin>
            <rdommax>3.632487</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_47_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congener 47; 2,2',4,4'-Tetrachlorobiphenyl. 
Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>S</edomv>
            <edomvd>Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>US</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_48_Conc</attrlabl>
        <attrdef>PCB congener 48; 2,2',4,5-Tetrachlorobiphenyl concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.000637</rdommin>
            <rdommax>3.295687</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_48_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congener 48; 2,2',4,5-Tetrachlorobiphenyl. 
Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>US</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample. Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_44_Conc</attrlabl>
        <attrdef>PCB congener 44; 2,2',3,5'-Tetrachlorobiphenyl concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.002993</rdommin>
            <rdommax>1.233102</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_44_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congener 44; 2,2',3,5'-Tetrachlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>US</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample. Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_37_Conc</attrlabl>
        <attrdef>PCB congener 37; 3,4,4'-Trichlorobiphenyl concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.000674</rdommin>
            <rdommax>2.404971</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_37_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congener 37; 3,4,4'-Trichlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>S</edomv>
            <edomvd>Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>E</edomv>
            <edomvd>Measured value above calibration limit; Estimated value.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_42_Conc</attrlabl>
        <attrdef>PCB congener 42; 2,2',3,4'-Tetrachlorobiphenyl concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.001069</rdommin>
            <rdommax>0.990208</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_42_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congener 42; 2,2',3,4'-Tetrachlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>US</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample. Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>E</edomv>
            <edomvd>Measured value above calibration limit; Estimated value.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_41_71_Conc</attrlabl>
        <attrdef>PCB congeners 41 and 71; 2,2',3,4-Tetrachlorobiphenyl and 2,3',4',6-Tetrachlorobiphenyl combined concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.001703</rdommin>
            <rdommax>1.471239</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_41_71_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congeners 41 and 71; 2,2',3,4-Tetrachlorobiphenyl and 2,3',4',6-Tetrachlorobiphenyl. 
Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>US</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample. Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_64_Conc</attrlabl>
        <attrdef>PCB congener 64; 2,3,4',6-Tetrachlorobiphenyl concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.000729</rdommin>
            <rdommax>0.648447</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_64_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congener 64; 2,3,4',6-Tetrachlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>US</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample. Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_40_Conc</attrlabl>
        <attrdef>PCB congener 40; 2,2',3,3'-Tetrachlorobiphenyl concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.000855</rdommin>
            <rdommax>9.44344</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_40_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congener 40; 2,2',3,3'-Tetrachlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>E</edomv>
            <edomvd>Measured value above calibration limit; Estimated value.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>S</edomv>
            <edomvd>Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>US</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample. Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_100_Conc</attrlabl>
        <attrdef>PCB congener 100; 2,2',4,4',6-Pentachlorobiphenyl concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Value not reported.</edomvd>
            <edomvds>USGS defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <rdom>
            <rdommin>0.000076</rdommin>
            <rdommax>1.089864</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_100_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congener 100; 2,2',4,4',6-Pentachlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>E</edomv>
            <edomvd>Measured value above calibration limit; Estimated value.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>UB</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample. Detection in trip/method/equipment blank; Value may be affected by contamination.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>S</edomv>
            <edomvd>Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>BS</edomv>
            <edomvd>Detection in trip/method/equipment blank; Value may be affected by contamination.
Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>EB</edomv>
            <edomvd>Measured value above calibration limit; Estimated value.
Detection in trip/method/equipment blank; Value may be affected by contamination.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>N</edomv>
            <edomvd>Limitations in passive sampler calibration/equilibration; Value not reported.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>HE</edomv>
            <edomvd>Relevant calibration check recovery &gt; 130%; Value may be biased high.
Measured value above calibration limit; Estimated value.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_63_Conc</attrlabl>
        <attrdef>PCB congener 63; 2,3,4',5-Tetrachlorobiphenyl concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Value not reported.</edomvd>
            <edomvds>USGS defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <rdom>
            <rdommin>0.000135</rdommin>
            <rdommax>1.494934</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_63_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congener 63; 2,3,4',5-Tetrachlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>S</edomv>
            <edomvd>Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>N</edomv>
            <edomvd>Limitations in passive sampler calibration/equilibration; Value not reported.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>E</edomv>
            <edomvd>Measured value above calibration limit; Estimated value.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_74_Conc</attrlabl>
        <attrdef>PCB congener 74; 2,4,4',5-Tetrachlorobiphenyl concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Value not reported.</edomvd>
            <edomvds>USGS defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <rdom>
            <rdommin>0.312346</rdommin>
            <rdommax>9.120595</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_74_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congener 74; 2,4,4',5-Tetrachlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>S</edomv>
            <edomvd>Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>US</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample. Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>N</edomv>
            <edomvd>Limitations in passive sampler calibration/equilibration; Value not reported.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_70_76_Conc</attrlabl>
        <attrdef>PCB congeners 70 and 76; 2,3',4',5-Tetrachlorobiphenyl and 2,3',4',5'-Tetrachlorobiphenyl combined concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Value not reported.</edomvd>
            <edomvds>USGS defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <rdom>
            <rdommin>0.000926</rdommin>
            <rdommax>1.307428</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_70_76_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congeners 70 and 76; 2,3',4',5-Tetrachlorobiphenyl and 2,3',4',5'-Tetrachlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>US</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample. Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>N</edomv>
            <edomvd>Limitations in passive sampler calibration/equilibration; Value not reported.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_66_95_Conc</attrlabl>
        <attrdef>PCB congeners 66 and 95; 2,3',4,4'-Tetrachlorobiphenyl and 2,2',3,5',6-Pentachlorobiphenyl combined concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Value not reported.</edomvd>
            <edomvds>USGS defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <rdom>
            <rdommin>0.001723</rdommin>
            <rdommax>9.235698</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_66_95_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congeners 66 and 95; 2,3',4,4'-Tetrachlorobiphenyl and 2,2',3,5',6-Pentachlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>S</edomv>
            <edomvd>Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>US</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample. Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>N</edomv>
            <edomvd>Limitations in passive sampler calibration/equilibration; Value not reported.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_91_Conc</attrlabl>
        <attrdef>PCB congener 91; 2,2',3,4',6-Pentachlorobiphenyl concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Value not reported.</edomvd>
            <edomvds>USGS defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <rdom>
            <rdommin>0.000317</rdommin>
            <rdommax>3.556579</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_91_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congener 91; 2,2',3,4',6-Pentachlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>S</edomv>
            <edomvd>Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>N</edomv>
            <edomvd>Limitations in passive sampler calibration/equilibration; Value not reported.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>E</edomv>
            <edomvd>Measured value above calibration limit; Estimated value.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_56_60_Conc</attrlabl>
        <attrdef>PCB congeners 56 and 60; 2,3,3',4'-Tetrachlorobiphenyl and 2,3,4,4'-Tetrachlorobiphenyl combined concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Value not reported.</edomvd>
            <edomvds>USGS defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <rdom>
            <rdommin>0.000986</rdommin>
            <rdommax>2.573036</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_56_60_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congeners 56 and 60; 2,3,3',4'-Tetrachlorobiphenyl and 2,3,4,4'-Tetrachlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>S</edomv>
            <edomvd>Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>US</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample. Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>N</edomv>
            <edomvd>Limitations in passive sampler calibration/equilibration; Value not reported.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_92_84_89_Conc</attrlabl>
        <attrdef>PCB congeners 92, 84 and 89; 2,2',3,5,5'-Pentachlorobiphenyl, 2,2',3,3',6-Pentachlorobiphenyl and 2,2',3,4,6'-Pentachlorobiphenyl combined concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Value not reported.</edomvd>
            <edomvds>USGS defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <rdom>
            <rdommin>0.000388</rdommin>
            <rdommax>19.087804</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_92_84_89_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congeners 92, 84 and 89; 2,2',3,5,5'-Pentachlorobiphenyl, 2,2',3,3',6-Pentachlorobiphenyl and 2,2',3,4,6'-Pentachlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>E</edomv>
            <edomvd>Measured value above calibration limit; Estimated value.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>S</edomv>
            <edomvd>Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>US</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample. Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>N</edomv>
            <edomvd>Limitations in passive sampler calibration/equilibration; Value not reported.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_101_Conc</attrlabl>
        <attrdef>PCB congener 101 ; 2,2',4,5,5'-Pentachlorobiphenyl concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Value not reported.</edomvd>
            <edomvds>USGS defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <rdom>
            <rdommin>0.000298</rdommin>
            <rdommax>7.478131</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_101_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congener 101; 2,2',4,5,5'-Pentachlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>S</edomv>
            <edomvd>Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>N</edomv>
            <edomvd>Limitations in passive sampler calibration/equilibration; Value not reported.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_99_Conc</attrlabl>
        <attrdef>PCB congener 99; 2,2',4,4',5-Pentachlorobiphenyl concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Value not reported.</edomvd>
            <edomvds>USGS defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <rdom>
            <rdommin>0.000143</rdommin>
            <rdommax>5.385386</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_99_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congener 99; 2,2',4,4',5-Pentachlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>S</edomv>
            <edomvd>Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>N</edomv>
            <edomvd>Limitations in passive sampler calibration/equilibration; Value not reported.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_83_Conc</attrlabl>
        <attrdef>PCB congener 83; 2,2',3,3',5-Pentachlorobiphenyl concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Value not reported..</edomvd>
            <edomvds>USGS defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <rdom>
            <rdommin>0.000143</rdommin>
            <rdommax>1.375892</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_83_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congener 83; 2,2',3,3',5-Pentachlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>S</edomv>
            <edomvd>Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>E</edomv>
            <edomvd>Measured value above calibration limit; Estimated value.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>N</edomv>
            <edomvd>Limitations in passive sampler calibration/equilibration; Value not reported.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_97_Conc</attrlabl>
        <attrdef>PCB congener 97; 2,2',3,4',5'-Pentachlorobiphenyl concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Value not reported..</edomvd>
            <edomvds>USGS defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <rdom>
            <rdommin>0.000235</rdommin>
            <rdommax>1.574998</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_97_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congener 97; 2,2',3,4',5'-Pentachlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>S</edomv>
            <edomvd>Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>N</edomv>
            <edomvd>Limitations in passive sampler calibration/equilibration; Value not reported.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_81_87_Conc</attrlabl>
        <attrdef>PCB congeners 81 and 87; 3,4,4',5-Tetrachlorobiphenyl and 2,2',3,4,5'-Pentachlorobiphenyl combined concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Value not reported.</edomvd>
            <edomvds>USGS defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <rdom>
            <rdommin>0.000508</rdommin>
            <rdommax>5.508887</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_81_87_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congeners 81 and 87; 3,4,4',5-Tetrachlorobiphenyl and 2,2',3,4,5'-Pentachlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>S</edomv>
            <edomvd>Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>N</edomv>
            <edomvd>Limitations in passive sampler calibration/equilibration; Value not reported.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_85_Conc</attrlabl>
        <attrdef>PCB congener 85; 2,2',3,4,4'-Pentachlorobiphenyl concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Value not reported.</edomvd>
            <edomvds>USGS defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <rdom>
            <rdommin>0.000132</rdommin>
            <rdommax>3.196504</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_85_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congener 85; 2,2',3,4,4'-Pentachlorobiphenyl. 
Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>S</edomv>
            <edomvd>Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>US</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample. Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>N</edomv>
            <edomvd>Limitations in passive sampler calibration/equilibration; Value not reported.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>E</edomv>
            <edomvd>Measured value above calibration limit; Estimated value.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_136_Conc</attrlabl>
        <attrdef>PCB congener 136; 2,2',3,3',6,6'-Hexachlorobiphenyl concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Value not reported.</edomvd>
            <edomvds>USGS defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <rdom>
            <rdommin>0.000201</rdommin>
            <rdommax>7.497751</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_136_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congener 136; 2,2',3,3',6,6'-Hexachlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>E</edomv>
            <edomvd>Measured value above calibration limit; Estimated value.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>US</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample. Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>N</edomv>
            <edomvd>Limitations in passive sampler calibration/equilibration; Value not reported.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_110_77_Conc</attrlabl>
        <attrdef>PCB congeners 110 and 77; 2,3,3',4',6-Pentachlorobiphenyl and 3,3',4,4'-Tetrachlorobiphenyl combined concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Value not reported.</edomvd>
            <edomvds>USGS defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <rdom>
            <rdommin>0.002680</rdommin>
            <rdommax>9.958579</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_110_77_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congeners 110 and 77; 2,3,3',4',6-Pentachlorobiphenyl and 3,3',4,4'-Tetrachlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>S</edomv>
            <edomvd>Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>N</edomv>
            <edomvd>Limitations in passive sampler calibration/equilibration; Value not reported.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>E</edomv>
            <edomvd>Measured value above calibration limit; Estimated value.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_82_151_Conc</attrlabl>
        <attrdef>PCB congeners 82 and 151; 2,2',3,3',4-Pentachlorobiphenyl and 2,2',3,5,5',6-Hexachlorobiphenyl combined concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Value not reported.</edomvd>
            <edomvds>USGS defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <rdom>
            <rdommin>0.000587</rdommin>
            <rdommax>14.745464</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_82_151_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congeners 82 and 151; 2,2',3,3',4-Pentachlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>S</edomv>
            <edomvd>Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>N</edomv>
            <edomvd>Limitations in passive sampler calibration/equilibration; Value not reported.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_135_144_Conc</attrlabl>
        <attrdef>PCB congeners 135 and 144; 2,2',3,3',5,6'-Hexachlorobiphenyl and 2,2',3,4,5',6-Hexachlorobiphenyl combined concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Value not reported.</edomvd>
            <edomvds>USGS defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <rdom>
            <rdommin>0.000078</rdommin>
            <rdommax>2.229211</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_135_144_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congeners 135 and 144; 2,2',3,3',5,6'-Hexachlorobiphenyl and 2,2',3,4,5',6-Hexachlorobipheny. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>S</edomv>
            <edomvd>Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>US</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>N</edomv>
            <edomvd>Limitations in passive sampler calibration/equilibration; Value not reported.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_107_Conc</attrlabl>
        <attrdef>PCB congener 107; 2,3,3',4',5-Pentachlorobiphenyl concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Value not reported.</edomvd>
            <edomvds>USGS defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <rdom>
            <rdommin>0.000010</rdommin>
            <rdommax>0.909323</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_107_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congener 107; 2,3,3',4',5-Pentachlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>S</edomv>
            <edomvd>Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>N</edomv>
            <edomvd>Limitations in passive sampler calibration/equilibration; Value not reported.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>E</edomv>
            <edomvd>Measured value above calibration limit; Estimated value.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_149_123_Conc</attrlabl>
        <attrdef>PCB congeners 149 and 123; 2,2',3,4',5',6-Hexachlorobiphenyl and 2,3',4,4',5'-Pentachlorobiphenyl combined concentrations expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Value not reported.</edomvd>
            <edomvds>USGS defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <rdom>
            <rdommin>0.000097</rdommin>
            <rdommax>6.535591</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_149_123_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congener 149 and 123; 2,2',3,4',5',6-Hexachlorobiphenyl and 2,3',4,4',5'-Pentachlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>S</edomv>
            <edomvd>Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>US</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>N</edomv>
            <edomvd>Limitations in passive sampler calibration/equilibration; Value not reported.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_118_Conc</attrlabl>
        <attrdef>PCB congener 118; 2,3',4,4',5-Pentachlorobiphenyl concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Value not reported.</edomvd>
            <edomvds>USGS defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <rdom>
            <rdommin>0.000257</rdommin>
            <rdommax>6.126348</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_118_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congener 118; 2,3',4,4',5-Pentachlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>S</edomv>
            <edomvd>Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>US</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample. Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>N</edomv>
            <edomvd>Limitations in passive sampler calibration/equilibration; Value not reported.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_134_Conc</attrlabl>
        <attrdef>PCB congener 134; 2,2',3,3',5,6-Hexachlorobiphenyl concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Value not reported.</edomvd>
            <edomvds>USGS defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <rdom>
            <rdommin>0.000008</rdommin>
            <rdommax>0.723400</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_134_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congener 134; 2,2',3,3',5,6-Hexachlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>E</edomv>
            <edomvd>Measured value above calibration limit; Estimated value.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>UB</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample. Detection in trip/method/equipment blank; Value may be affected by contamination.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>S</edomv>
            <edomvd>Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>US</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample. Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>H</edomv>
            <edomvd>Relevant calibration check recovery &gt; 130%; Value may be biased high.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>HE</edomv>
            <edomvd>Detection in trip/method/equipment blank; Value may be affected by contamination.
Measured value above calibration limit; Estimated value.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>N</edomv>
            <edomvd>Limitations in passive sampler calibration/equilibration; Value not reported.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_114_131_Conc</attrlabl>
        <attrdef>PCB congeners 114 and 131; 2,3,4,4',5-Pentachlorobiphenyl and 2,2',3,3',4,6-Hexachlorobiphenyl combined concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Value not reported.</edomvd>
            <edomvds>USGS defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <rdom>
            <rdommin>0.000019</rdommin>
            <rdommax>1.403649</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_114_131_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congeners 114 and 131; 2,3,4,4',5-Pentachlorobiphenyl and 2,2',3,3',4,6-Hexachlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>HB</edomv>
            <edomvd>Relevant calibration check recovery &gt; 130%; Value may be biased high. Detection in trip/method/equipment blank; Value may be affected by contamination.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>EHB</edomv>
            <edomvd>Measured value above calibration limit; Estimated value. Relevant calibration check recovery &gt; 130%; Value may be biased high. Detection in trip/method/equipment blank; Value may be affected by contamination.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>UHB</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample. Relevant calibration check recovery &gt; 130%; Value may be biased high. Detection in trip/method/equipment blank; Value may be affected by contamination.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>S</edomv>
            <edomvd>Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>UL</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample. Relevant calibration check recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>L</edomv>
            <edomvd>Relevant calibration check recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>LS</edomv>
            <edomvd>Relevant calibration check recovery &lt; 70%; Value may be biased low.
Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>HEB</edomv>
            <edomvd>Relevant calibration check recovery &gt; 130%; Value may be biased high.
; Measured value above calibration limit; Estimated value. Detection in trip/method/equipment blank; Value may be affected by contamination.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>N</edomv>
            <edomvd>Limitations in passive sampler calibration/equilibration; Value not reported.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>H</edomv>
            <edomvd>Relevant calibration check recovery &gt; 130%; Value may be biased high.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>LE</edomv>
            <edomvd>Relevant calibration check recovery &lt; 70%; Value may be biased low.
Measured value above calibration limit; Estimated value.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_146_Conc</attrlabl>
        <attrdef>PCB congener 146; 2,2',3,4',5,5'-Hexachlorobiphenyl concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Value not reported.</edomvd>
            <edomvds>USGS defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <rdom>
            <rdommin>0.000083</rdommin>
            <rdommax>2.274264</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_146_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congener 146; 2,2',3,4',5,5'-Hexachlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>S</edomv>
            <edomvd>Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>US</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>B</edomv>
            <edomvd>Detection in trip/method/equipment blank; Value may be affected by contamination.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>N</edomv>
            <edomvd>Limitations in passive sampler calibration/equilibration; Value not reported.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_153_Conc</attrlabl>
        <attrdef>PCB congener 153; 2,2',4,4',5,5'-Hexachlorobiphenyl concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Value not reported.</edomvd>
            <edomvds>USGS defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <rdom>
            <rdommin>0.000708</rdommin>
            <rdommax>7.392104</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_153_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congener 153; 2,2',4,4',5,5'-Hexachlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>S</edomv>
            <edomvd>Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>US</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample. Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>B</edomv>
            <edomvd>Detection in trip/method/equipment blank; Value may be affected by contamination.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>N</edomv>
            <edomvd>Limitations in passive sampler calibration/equilibration; Value not reported.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_132_Conc</attrlabl>
        <attrdef>PCB congener 132; 2,2',3,3',4,6'-Hexachlorobiphenyl concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Value not reported..</edomvd>
            <edomvds>USGS defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <rdom>
            <rdommin>0.000129</rdommin>
            <rdommax>4.101976</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_132_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congener 132; 2,2',3,3',4,6'-Hexachlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>S</edomv>
            <edomvd>Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>US</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample. Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>N</edomv>
            <edomvd>Limitations in passive sampler calibration/equilibration; Value not reported.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_105_Conc</attrlabl>
        <attrdef>PCB congener 105; 2,3,3',4,4'-Pentachlorobiphenyl concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Value not reported.</edomvd>
            <edomvds>USGS defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <rdom>
            <rdommin>0.000010</rdommin>
            <rdommax>0.299908</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_105_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congener 105; 2,3,3',4,4'-Pentachlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>S</edomv>
            <edomvd>Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>US</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample. Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>N</edomv>
            <edomvd>Limitations in passive sampler calibration/equilibration; Value not reported.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_141_Conc</attrlabl>
        <attrdef>PCB congener 141; 2,2',3,4,5,5'-Hexachlorobiphenyl concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Value not reported.</edomvd>
            <edomvds>USGS defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <rdom>
            <rdommin>0.000102</rdommin>
            <rdommax>1.087120</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_141_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congener 141; 2,2',3,4,5,5'-Hexachlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>US</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample. Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>N</edomv>
            <edomvd>Limitations in passive sampler calibration/equilibration; Value not reported.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_137_176_130_Conc</attrlabl>
        <attrdef>PCB congeners 137, 176 and 130; 2,2',3,4,4',5-Hexachlorobiphenyl, 2,2',3,3',4,6,6'-Heptachlorobiphenyl and 2,2',3,3',4,5'-Hexachlorobiphenyl combined concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Value not reported.</edomvd>
            <edomvds>USGS defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <rdom>
            <rdommin>0.000018</rdommin>
            <rdommax>0.685081</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_137_176_130_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congener 137; 2,2',3,4,4',5-Hexachlorobiphenyl, 2,2',3,3',4,6,6'-Heptachlorobiphenyl and 2,2',3,3',4,5'-Hexachlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>S</edomv>
            <edomvd>Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>US</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample. Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>N</edomv>
            <edomvd>Limitations in passive sampler calibration/equilibration; Value not reported.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>E</edomv>
            <edomvd>Measured value above calibration limit; Estimated value.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_163_138_Conc</attrlabl>
        <attrdef>PCB congeners 163 and 138; 2,3,3',4',5,6-Hexachlorobiphenyl and 2,2',3,4,4',5'-Hexachlorobiphenyl combined concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Value not reported..</edomvd>
            <edomvds>USGS defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <rdom>
            <rdommin>0.000192</rdommin>
            <rdommax>13.148039</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_163_138_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congeners 163 and 138; 2,3,3',4',5,6-Hexachlorobiphenyl and 2,2',3,4,4',5'-Hexachlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>S</edomv>
            <edomvd>Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>US</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample. Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>N</edomv>
            <edomvd>Limitations in passive sampler calibration/equilibration; Value not reported.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_158_Conc</attrlabl>
        <attrdef>PCB congener 158; 2,3,3',4,4',6-Hexachlorobiphenyl concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Value not reported..</edomvd>
            <edomvds>USGS defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <rdom>
            <rdommin>0.000018</rdommin>
            <rdommax>2.497004</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_158_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congener 158; 2,3,3',4,4',6-Hexachlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>E</edomv>
            <edomvd>Measured value above calibration limit; Estimated value.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>S</edomv>
            <edomvd>Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>N</edomv>
            <edomvd>Limitations in passive sampler calibration/equilibration; Value not reported.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>B</edomv>
            <edomvd>Detection in trip/method/equipment blank; Value may be affected by contamination.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_178_129_Conc</attrlabl>
        <attrdef>PCB congener 178 and 129; 2,2',3,3',5,5',6-Heptachlorobiphenyl and 2,2',3,3',4,5-Hexachlorobiphenyl combined concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Value not reported..</edomvd>
            <edomvds>USGS defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <rdom>
            <rdommin>0.000044</rdommin>
            <rdommax>3.189887</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_178_129_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congeners 178 and 129; 2,2',3,3',5,5',6-Heptachlorobiphenyl and 2,2',3,3',4,5-Hexachlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>S</edomv>
            <edomvd>Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>US</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample. Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>N</edomv>
            <edomvd>Limitations in passive sampler calibration/equilibration; Value not reported.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_175_Conc</attrlabl>
        <attrdef>PCB congener 175; 2,2',3,3'4,5',6-Heptachlorobiphenyl concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Value not reported..</edomvd>
            <edomvds>USGS defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <rdom>
            <rdommin>0.000010</rdommin>
            <rdommax>0.129602</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_175_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congener 175; 2,2',3,3'4,5',6-Heptachlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>US</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample. Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>B</edomv>
            <edomvd>Detection in trip/method/equipment blank; Value may be affected by contamination.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>N</edomv>
            <edomvd>Limitations in passive sampler calibration/equilibration; Value not reported.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_187_182_Conc</attrlabl>
        <attrdef>PCB congeners 187 and 182; 2,2',3,4',5,5',6-Heptachlorobiphenyl and 2,2',3,4,4',5,6'-Heptachlorobiphenyl combined concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Value not reported..</edomvd>
            <edomvds>USGS defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <rdom>
            <rdommin>0.000091</rdommin>
            <rdommax>2.756467</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_187_182_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congeners 187 and 182; 2,2',3,4',5,5',6-Heptachlorobiphenyl and 2,2',3,4,4',5,6'-Heptachlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>US</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample. Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>N</edomv>
            <edomvd>Limitations in passive sampler calibration/equilibration; Value not reported.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_183_Conc</attrlabl>
        <attrdef>PCB congener 183; 2,2',3,4,4',5',6-Heptachlorobiphenyl concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Value not reported.</edomvd>
            <edomvds>Producer defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <rdom>
            <rdommin>0.000042</rdommin>
            <rdommax>1.916794</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_183_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congener 183; 2,2',3,4,4',5',6-Heptachlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>S</edomv>
            <edomvd>Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>US</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample. Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>N</edomv>
            <edomvd>Limitations in passive sampler calibration/equilibration; Value not reported.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_128_Conc</attrlabl>
        <attrdef>PCB congener 128; 2,2',3,3',4,4'-Hexachlorobiphenyl concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Value not reported..</edomvd>
            <edomvds>USGS defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <rdom>
            <rdommin>0.000129</rdommin>
            <rdommax>1.004722</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_128_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congener 128; 2,2',3,3',4,4'-Hexachlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>E</edomv>
            <edomvd>Measured value above calibration limit; Estimated value.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>EB</edomv>
            <edomvd>Measured value above calibration limit; Estimated value. Detection in trip/method/equipment blank; Value may be affected by contamination.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>S</edomv>
            <edomvd>Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>N</edomv>
            <edomvd>Limitations in passive sampler calibration/equilibration; Value not reported.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>L</edomv>
            <edomvd>Relevant calibration check recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>LE</edomv>
            <edomvd>Relevant calibration check recovery &lt; 70%; Value may be biased low.
Measured value above calibration limit; Estimated value.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_185_Conc</attrlabl>
        <attrdef>PCB congener 185; 2,2',3,4,5,5',6-Heptachlorobiphenyl concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Value not reported..</edomvd>
            <edomvds>USGS defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <rdom>
            <rdommin>0.000013</rdommin>
            <rdommax>0.324623</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_185_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congener 185; 2,2',3,4,5,5',6-Heptachlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>US</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample. Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>N</edomv>
            <edomvd>Limitations in passive sampler calibration/equilibration; Value not reported.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_174_Conc</attrlabl>
        <attrdef>PCB congener 174; 2,2',3,3',4,5,6'-Heptachlorobiphenyl concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Value not reported..</edomvd>
            <edomvds>USGS defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <rdom>
            <rdommin>0.000088</rdommin>
            <rdommax>2.874774</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_174_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congener 174; 2,2',3,3',4,5,6'-Heptachlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>S</edomv>
            <edomvd>Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>US</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample. Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>N</edomv>
            <edomvd>Limitations in passive sampler calibration/equilibration; Value not reported.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_177_Conc</attrlabl>
        <attrdef>PCB congener 177; 2,2',3,3',4,5',6'-Heptachlorobiphenyl concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Value not reported..</edomvd>
            <edomvds>USGS defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <rdom>
            <rdommin>0.000053</rdommin>
            <rdommax>2.140744</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_177_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congener 177; 2,2',3,3',4,5',6'-Heptachlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>S</edomv>
            <edomvd>Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>US</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample. Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>N</edomv>
            <edomvd>Limitations in passive sampler calibration/equilibration; Value not reported.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_202_171_156_Conc</attrlabl>
        <attrdef>PCB congeners 202, 171 and 156; 2,2',3,3',5,5',6,6'-Octachlorobiphenyl, 2,2',3,3',4,4',6-Heptachlorobiphenyl and 2,3,3',4,4',5-Hexachlorobiphenyl combined concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Value not reported..</edomvd>
            <edomvds>USGS defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <rdom>
            <rdommin>0.000019</rdommin>
            <rdommax>0.434597</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_202_171_156_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congeners 202, 171 and 156; 2,2',3,3',5,5',6,6'-Octachlorobiphenyl, 2,2',3,3',4,4',6-Heptachlorobiphenyl and 2,3,3',4,4',5-Hexachlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>US</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample. Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>N</edomv>
            <edomvd>Limitations in passive sampler calibration/equilibration; Value not reported.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>E</edomv>
            <edomvd>Measured value above calibration limit; Estimated value.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_157_200_Conc</attrlabl>
        <attrdef>PCB congeners 157 and 200; 2,3,3',4,4',5'-Hexachlorobiphenyl and 2,2',3,3',4,5,6,6'-Octachlorobiphenyl combined concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Value not reported..</edomvd>
            <edomvds>USGS defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <rdom>
            <rdommin>0.000011</rdommin>
            <rdommax>3.872505</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_157_200_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congeners 157 and 200; 2,3,3',4,4',5'-Hexachlorobiphenyl and 2,2',3,3',4,5,6,6'-Octachlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>E</edomv>
            <edomvd>Measured value above calibration limit; Estimated value.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>S</edomv>
            <edomvd>Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>US</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample. Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>N</edomv>
            <edomvd>Limitations in passive sampler calibration/equilibration; Value not reported.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_172_197_Conc</attrlabl>
        <attrdef>PCB congeners 172 and 197; 2,2',3,3',4,5,5'-Heptachlorobiphenyl and 2,2',3,3',4,4',6,6'-Octachlorobiphenyl combined concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Value not reported..</edomvd>
            <edomvds>USGS defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <rdom>
            <rdommin>0.114971</rdommin>
            <rdommax>0.906264</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_172_197_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congeners 172 and 197; 2,2',3,3',4,5,5'-Heptachlorobiphenyl and 2,2',3,3',4,4',6,6'-Octachlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>S</edomv>
            <edomvd>Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>US</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample. Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>N</edomv>
            <edomvd>Limitations in passive sampler calibration/equilibration; Value not reported.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_180_Conc</attrlabl>
        <attrdef>PCB congener 180; 2,2',3,4,4',5,5'-Heptachlorobiphenyl concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Value not reported..</edomvd>
            <edomvds>USGS defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <rdom>
            <rdommin>0.000101</rdommin>
            <rdommax>6.731114</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_180_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congener 180; 2,2',3,4,4',5,5'-Heptachlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>S</edomv>
            <edomvd>Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>US</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample. Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>N</edomv>
            <edomvd>Limitations in passive sampler calibration/equilibration; Value not reported.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_193_Conc</attrlabl>
        <attrdef>PCB congener 193; 2,3,3',4',5,5',6-Heptachlorobiphenyl concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Value not reported..</edomvd>
            <edomvds>USGS defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <rdom>
            <rdommin>0.053833</rdommin>
            <rdommax>0.070693</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_193_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congener 193; 2,3,3',4',5,5',6-Heptachlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>US</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample. Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>N</edomv>
            <edomvd>Limitations in passive sampler calibration/equilibration; Value not reported.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_191_Conc</attrlabl>
        <attrdef>PCB congener 191; 2,3,3',4,4',5',6-Heptachlorobiphenyl concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Value not reported..</edomvd>
            <edomvds>USGS defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <rdom>
            <rdommin>0.019737</rdommin>
            <rdommax>0.207702</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_191_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congener 191; 2,3,3',4,4',5',6-Heptachlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>H</edomv>
            <edomvd>Relevant calibration check recovery &gt; 130%; Value may be biased high.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>UH</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample. Relevant calibration check recovery &gt; 130%; Value may be biased high.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>S</edomv>
            <edomvd>Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>B</edomv>
            <edomvd>Detection in trip/method/equipment blank; Value may be affected by contamination.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>UB</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample. Detection in trip/method/equipment blank; Value may be affected by contamination.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>BS</edomv>
            <edomvd>Detection in trip/method/equipment blank; Value may be affected by contamination.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>N</edomv>
            <edomvd>Limitations in passive sampler calibration/equilibration; Value not reported.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_199_Conc</attrlabl>
        <attrdef>PCB congener 199; 2,2',3,3',4,5,5',6'-Octachlorobiphenyl concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Value not reported..</edomvd>
            <edomvds>USGS defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <rdom>
            <rdommin>0.000012</rdommin>
            <rdommax>0.191543</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_199_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congener 199; 2,2',3,3',4,5,5',6'-Octachlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>US</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample. Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>N</edomv>
            <edomvd>Limitations in passive sampler calibration/equilibration; Value not reported.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_170_190_Conc</attrlabl>
        <attrdef>PCB congeners 170 and 190; 2,2',3,3',4,4',5-Heptachlorobiphenyl and 2,3,3',4,4',5,6-Heptachlorobiphenyl combined concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Value not reported..</edomvd>
            <edomvds>USGS defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <rdom>
            <rdommin>0.000035</rdommin>
            <rdommax>3.019792</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_170_190_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congeners 170 and 190; 2,2',3,3',4,4',5-Heptachlorobiphenyl and 2,3,3',4,4',5,6-Heptachlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>S</edomv>
            <edomvd>Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>US</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample. Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>N</edomv>
            <edomvd>Limitations in passive sampler calibration/equilibration; Value not reported.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_198_Conc</attrlabl>
        <attrdef>PCB congener 198; 2,2',3,3',4,5,5',6-Octachlorobiphenyl concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Value not reported..</edomvd>
            <edomvds>USGS defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <rdom>
            <rdommin>0.015381</rdommin>
            <rdommax>0.156059</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_198_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congener 198; 2,2',3,3',4,5,5',6-Octachlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>US</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample. Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>N</edomv>
            <edomvd>Limitations in passive sampler calibration/equilibration; Value not reported.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_201_Conc</attrlabl>
        <attrdef>PCB congener 201; 2,2',3,3',4,5',6,6'-Octachlorobiphenyl concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Value not reported..</edomvd>
            <edomvds>USGS defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <rdom>
            <rdommin>0.538333</rdommin>
            <rdommax>3.019215</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_201_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congener 201; 2,2',3,3',4,5',6,6'-Octachlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>US</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample. Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>N</edomv>
            <edomvd>Limitations in passive sampler calibration/equilibration; Value not reported.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_203_196_Conc</attrlabl>
        <attrdef>PCB congeners 203 and 196; 2,2',3,4,4',5,5',6-Octachlorobiphenyl and 2,2',3,3',4,4',5,6'-Octachlorobiphenyl combined concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Value not reported..</edomvd>
            <edomvds>USGS defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <rdom>
            <rdommin>0.551022</rdommin>
            <rdommax>2.651109</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_203_196_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congeners 203 and 196; 2,2',3,4,4',5,5',6-Octachlorobiphenyl and 2,2',3,3',4,4',5,6'-Octachlorobiphenyl. 
Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>US</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample. Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>N</edomv>
            <edomvd>Limitations in passive sampler calibration/equilibration; Value not reported.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_208_195_Conc</attrlabl>
        <attrdef>PCB congeners 208 and 195; 2,2',3,3',4,5,5',6,6'-Nonachlorobiphenyl and 2,2',3,3',4,4',5,6-Octachlorobiphenyl combined concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Value not reported..</edomvd>
            <edomvds>USGS defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <rdom>
            <rdommin>0.102514</rdommin>
            <rdommax>0.498903</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_208_195_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congeners 208 and 195; 2,2',3,3',4,5,5',6,6'-Nonachlorobiphenyl and 2,2',3,3',4,4',5,6-Octachlorobiphenyl. 
Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>US</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample. Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>N</edomv>
            <edomvd>Limitations in passive sampler calibration/equilibration; Value not reported.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_207_Conc</attrlabl>
        <attrdef>PCB 207;2,2',3,3',4,4',5,6,6'-Nonachlorobiphenyl concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Value not reported..</edomvd>
            <edomvds>USGS defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <rdom>
            <rdommin>0.014803</rdommin>
            <rdommax>0.069439</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_207_QA</attrlabl>
        <attrdef>Quality assurance check for PCB 207;2,2',3,3',4,4',5,6,6'-Nonachlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>UB</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample. Detection in trip/method/equipment blank; Value may be affected by contamination.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>B</edomv>
            <edomvd>Detection in trip/method/equipment blank; Value may be affected by contamination.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>S</edomv>
            <edomvd>Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>US</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample. Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>N</edomv>
            <edomvd>Limitations in passive sampler calibration/equilibration; Value not reported.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_194_Conc</attrlabl>
        <attrdef>PCB congener 194; 2,2',3,3',4,4',5,5'-Octachlorobiphenyl concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Value not reported..</edomvd>
            <edomvds>USGS defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <rdom>
            <rdommin>0.296062</rdommin>
            <rdommax>11.509573</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_194_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congener 194; 2,2',3,3',4,4',5,5'-Octachlorobiphenyl. 
Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>UL</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample. Relevant calibration check recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>LS</edomv>
            <edomvd>Relevant calibration check recovery &lt; 70%; Value may be biased low.
Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>L</edomv>
            <edomvd>Relevant calibration check recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>N</edomv>
            <edomvd>Limitations in passive sampler calibration/equilibration; Value not reported.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_205_Conc</attrlabl>
        <attrdef>PCB congener 205; 2,3,3',4,4',5,5',6-Octachlorobipheny concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Value not reported..</edomvd>
            <edomvds>USGS defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <rdom>
            <rdommin>0.012689</rdommin>
            <rdommax>0.701860</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_205_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congener 205; 2,3,3',4,4',5,5',6-Octachlorobipheny. 
Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>UL</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample. Relevant calibration check recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>ULS</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample. Relevant calibration check recovery &lt; 70%; Value may be biased low.
Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>L</edomv>
            <edomvd>Relevant calibration check recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>N</edomv>
            <edomvd>Limitations in passive sampler calibration/equilibration; Value not reported.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_206_Conc</attrlabl>
        <attrdef>PCB congener 206; 2,2',3,3',4,4',5,5',6-Nonachlorobiphenyl oncentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Value not reported..</edomvd>
            <edomvds>USGS defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <rdom>
            <rdommin>0.087287</rdommin>
            <rdommax>0.775238</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_206_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congener 206; 2,2',3,3',4,4',5,5',6-Nonachlorobiphenyl. 
Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Qualifier does not apply; Reported value is the concentration.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>UL</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample. Relevant calibration check recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>ULS</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample. Relevant calibration check recovery &lt; 70%; Value may be biased low.
Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>N</edomv>
            <edomvd>Limitations in passive sampler calibration/equilibration; Value not reported.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_209_Conc</attrlabl>
        <attrdef>PCB congener 209; Decachlorobiphenyl concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Value not reported..</edomvd>
            <edomvds>USGS defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <rdom>
            <rdommin>0.001974</rdommin>
            <rdommax>0.121053</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PCB_209_QA</attrlabl>
        <attrdef>Quality assurance check for PCB congener 209; Decachlorobiphenyl. Concentrations associated with a qualifier will have one or more letter codes in this field. 
Absence of qualifiers is also noted.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>UHB</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample. Relevant calibration check recovery &gt; 130%; Value may be biased high. Detection in trip/method/equipment blank; Value may be affected by contamination.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>UH</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample. Relevant calibration check recovery &gt; 130%; Value may be biased high.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>H</edomv>
            <edomvd>Relevant calibration check recovery &gt; 130%; Value may be biased high.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>UL</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample. Relevant calibration check recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>ELS</edomv>
            <edomvd>Measured value above calibration limit; Estimated value. Relevant calibration check recovery &lt; 70%; Value may be biased low.
Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>EL</edomv>
            <edomvd>Measured value above calibration limit; Estimated value.
Relevant calibration check recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>ELB</edomv>
            <edomvd>Measured value above calibration limit; Estimated value. Relevant calibration check recovery &lt; 70%; Value may be biased low. Detection in trip/method/equipment blank; Value may be affected by contamination.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>UB</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample. Detection in trip/method/equipment blank; Value may be affected by contamination.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>US</edomv>
            <edomvd>Measured value below calibration limit; Value represents lower LOQ for specific sample. Surrogate recovery &lt; 70%; Value may be biased low.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>N</edomv>
            <edomvd>Limitations in passive sampler calibration/equilibration; Value not reported.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
    </detailed>
    <detailed>
      <enttyp>
        <enttypl>Patapsco_PotomacWWTP_PFAS_Data.csv</enttypl>
        <enttypd>Comma Separated Value (CSV) file containing PFAS concentrations and associated quality control information in aqueous influent , effluent, blank samples, and biosolid samples collected from wastewater treatment plants within the Patapsco and Potomac watersheds, December 2021 through March 2023.</enttypd>
        <enttypds>UMBC Defined</enttypds>
      </enttyp>
      <attr>
        <attrlabl>Sample_ID</attrlabl>
        <attrdef>USGS generated unique sample identifier.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <udom>Each sample was given a unique sequential number by the USGS that corresponds with the sample name for each specific site.</udom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Sample_Name</attrlabl>
        <attrdef>Origin of wastewater or biosolids sample.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <udom>Each site was given a unique name identifier.</udom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Collection_Date</attrlabl>
        <attrdef>Date when the sample was collected from the site.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>12/20/2021</rdommin>
            <rdommax>3/23/2023</rdommax>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Watershed</attrlabl>
        <attrdef>Watershed in which the site is located.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>Patapsco</edomv>
            <edomvd>Affected watershed</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>Potomac</edomv>
            <edomvd>Affected watershed</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Sample_Type</attrlabl>
        <attrdef>Sample source type</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>Trip Blank AQ</edomv>
            <edomvd>Deionized water sample collected in the laboratory.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>Equipment Blank AQ</edomv>
            <edomvd>Deionized water sample collected in the field.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>Effluent</edomv>
            <edomvd>Water discharged into a waterway after the wastewater treatment process.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>Influent</edomv>
            <edomvd>Untreated wastewater or raw sewage entering the wastewater treatment plant.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>Trip Blank BS</edomv>
            <edomvd>Clean sand sample collected in the laboratory.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>Equipment Blank BS</edomv>
            <edomvd>Clean sand sample collected in the field.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>Biosolids</edomv>
            <edomvd>Dewatered and treated solid residuals of the wastewater treatment plant.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Concentration_Units</attrlabl>
        <attrdef>PFAS compound concentration units are in nanograms per gram of dry weight for biosolids (BS) samples and nanograms per liter for aqueous (AQ) samples.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <udom>PFAS compound concentration units are in nanograms per gram of dry weight for biosolids (BS) samples and nanograms per liter for aqueous (AQ) samples.</udom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFBA_Conc</attrlabl>
        <attrdef>Perfluorobutanoic acid concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.2</rdommin>
            <rdommax>70.8</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFBA_QA</attrlabl>
        <attrdef>Quality assurance check for perfluorobutanoic acid. 
Concentrations with a qualifier will have one or more letter codes in this field. Absence of qualifiers is also noted.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Associated concentration is less than the LOD and reported as the LOD.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>J</edomv>
            <edomvd>Associated concentration is less than the LOQ; The analyte was positively identified, and the concentrations was estimated as the LOQ divided by 2.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Not applicable; No corresponding qualifiers associated with the concentration.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>UB</edomv>
            <edomvd>Associated concentration is less than the LOD and reported as the LOD.
Compound present in lab, trip, or equipment blank; Blank is above the LOD.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>B</edomv>
            <edomvd>Compound present in lab, trip, or equipment blank; Blank is above the LOD.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFBA_SD</attrlabl>
        <attrdef>Perfluorobutanoic acid standard deviation of lab replicate concentrations expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-</rdommin>
            <rdommax>10.8</rdommax>
            <attrunit>Calculated standard deviation value.</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFPeA_Conc</attrlabl>
        <attrdef>Perfluoropentanoic acid concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.2</rdommin>
            <rdommax>86.7</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFPeA_QA</attrlabl>
        <attrdef>Quality assurance check for perfluoropentanoic acid. 
Concentrations with a qualifier will have one or more letter codes in this field. Absence of qualifiers is also noted.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Associated concentration is less than the LOD and reported as the LOD.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Not applicable; No corresponding qualifiers associated with the concentration.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>J</edomv>
            <edomvd>Associated concentration is less than the LOQ; The analyte was positively identified, and the concentrations was estimated as the LOQ divided by 2.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>UB</edomv>
            <edomvd>Associated concentration is less than the LOD and reported as the LOD.
Compound present in lab, trip, or equipment blank; Blank is above the LOD.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>B</edomv>
            <edomvd>Compound present in lab, trip, or equipment blank; Blank is above the LOD.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFPeA_SD</attrlabl>
        <attrdef>Perfluoropentanoic acid standard deviation of lab replicate concentrations expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-</rdommin>
            <rdommax>8.3</rdommax>
            <attrunit>Calculated standard deviation value.</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFBS_Conc</attrlabl>
        <attrdef>Perfluorobutane sulfonic acid concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.2</rdommin>
            <rdommax>26.0</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFBS_QA</attrlabl>
        <attrdef>Quality assurance check for perfluorobutane sulfonic acid. Concentrations with a qualifier will have one or more letter codes in this field. Absence of qualifiers is also noted.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Associated concentration is less than the LOD and reported as the LOD.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Not applicable; No corresponding qualifiers associated with the concentration.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>J</edomv>
            <edomvd>Associated concentration is less than the LOQ; The analyte was positively identified, and the concentrations was estimated as the LOQ divided by 2.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFBS_SD</attrlabl>
        <attrdef>Perfluorobutane sulfonic acid standard deviation of lab replicate concentrations expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-</rdommin>
            <rdommax>3.6</rdommax>
            <attrunit>Calculated standard deviation value.</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>4_2FTS_Conc</attrlabl>
        <attrdef>1H, 1H, 2H, 2H-perfluorohexane sulfonic acid concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.1</rdommin>
            <rdommax>4.9</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>4_2FTS_QA</attrlabl>
        <attrdef>Quality assurance check for 1H, 1H, 2H, 2H-perfluorohexane sulfonic acid. 
Concentrations with a qualifier will have one or more letter codes in this field. Absence of qualifiers is also noted.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Associated concentration is less than the LOD and reported as the LOD.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>J</edomv>
            <edomvd>Associated concentration is less than the LOQ; The analyte was positively identified, and the concentrations was estimated as the LOQ divided by 2.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Not applicable; No corresponding qualifiers associated with the concentration.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>4_2FTS_SD</attrlabl>
        <attrdef>1H, 1H, 2H, 2H-perfluorohexane sulfonic acid standard deviation of lab replicate concentrations expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-</rdommin>
            <rdommax>1</rdommax>
            <attrunit>Calculated standard deviation value..</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFHxA_Conc</attrlabl>
        <attrdef>Perfluorohexanoic acid concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.1</rdommin>
            <rdommax>101.0</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFHxA_QA</attrlabl>
        <attrdef>Quality assurance check for perfluorohexanoic acid. 
Concentrations with a qualifier will have one or more letter codes in this field. Absence of qualifiers is also noted.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Associated concentration is less than the LOD and reported as the LOD.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>J</edomv>
            <edomvd>Associated concentration is less than the LOQ; The analyte was positively identified, and the concentrations was estimated as the LOQ divided by 2.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Not applicable; No corresponding qualifiers associated with the concentration.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>UB</edomv>
            <edomvd>Associated concentration is less than the LOD and reported as the LOD.
Compound present in lab, trip, or equipment blank; Blank is above the LOD.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>B</edomv>
            <edomvd>Compound present in lab, trip, or equipment blank; Blank is above the LOD.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFHxA_SD</attrlabl>
        <attrdef>Perfluorohexanoic acid standard deviation of lab replicate concentrations expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-</rdommin>
            <rdommax>19.9</rdommax>
            <attrunit>Calculated standard deviation value.</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFPeS_Conc</attrlabl>
        <attrdef>Perfluropentane sulfonic acid concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.1</rdommin>
            <rdommax>10.7</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFPeS_QA</attrlabl>
        <attrdef>Quality assurance check for perfluropentane sulfonic acid. 
Concentrations with a qualifier will have one or more letter codes in this field. Absence of qualifiers is also noted.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Associated concentration is less than the LOD and reported as the LOD.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>J</edomv>
            <edomvd>Associated concentration is less than the LOQ; The analyte was positively identified, and the concentrations was estimated as the LOQ divided by 2.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Not applicable; No corresponding qualifiers associated with the concentration.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFPeS_SD</attrlabl>
        <attrdef>Perfluropentane sulfonic acid standard deviation of lab replicate concentrations expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.2</rdommin>
            <rdommax>7.2</rdommax>
            <attrunit>Calculated standard deviation value.</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>HFPO_DA_Conc</attrlabl>
        <attrdef>Hexafluoropropylene oxide dimer acid concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.4</rdommin>
            <rdommax>54.0</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>HFPO_DA_QA</attrlabl>
        <attrdef>Quality assurance check for hexafluoropropylene oxide dimer acid. 
Concentrations with a qualifier will have one or more letter codes in this field. Absence of qualifiers is also noted.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Associated concentration is less than the LOD and reported as the LOD.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>J</edomv>
            <edomvd>Associated concentration is less than the LOQ; The analyte was positively identified, and the concentrations was estimated as the LOQ divided by 2.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>HFPO_DA_SD</attrlabl>
        <attrdef>Hexafluoropropylene oxide dimer acid standard deviation of lab replicate concentrations expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-</rdommin>
            <rdommax>-</rdommax>
            <attrunit>Calculated standard deviation value.</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFHpA_Conc</attrlabl>
        <attrdef>Perfluoroheptanoic acid concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.1</rdommin>
            <rdommax>30.3</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFHpA_QA</attrlabl>
        <attrdef>Quality assurance check for perfluoroheptanoic acid. 
Concentrations with a qualifier will have one or more letter codes in this field. Absence of qualifiers is also noted.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Associated concentration is less than the LOD and reported as the LOD.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>J</edomv>
            <edomvd>Associated concentration is less than the LOQ; The analyte was positively identified, and the concentrations was estimated as the LOQ divided by 2.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Not applicable; No corresponding qualifiers associated with the concentration.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFHpA_SD</attrlabl>
        <attrdef>Perfluoroheptanoic acid standard deviation of lab replicate concentrations expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-</rdommin>
            <rdommax>11.3</rdommax>
            <attrunit>Calculated standard deviation value.</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFHxS_Conc</attrlabl>
        <attrdef>Perfluorohexane sulfonic acid concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.2</rdommin>
            <rdommax>148.0</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFHxS_QA</attrlabl>
        <attrdef>Quality assurance check for perfluorohexane sulfonic acid. 
Concentrations with a qualifier will have one or more letter codes in this field. Absence of qualifiers is also noted.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Associated concentration is less than the LOD and reported as the LOD.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>J</edomv>
            <edomvd>Associated concentration is less than the LOQ; The analyte was positively identified, and the concentrations was estimated as the LOQ divided by 2.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Not applicable; No corresponding qualifiers associated with the concentration.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFHxS_SD</attrlabl>
        <attrdef>Perfluorohexane sulfonic acid standard deviation of lab replicate concentrations expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-</rdommin>
            <rdommax>32.2</rdommax>
            <attrunit>Calculated standard deviation value.</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>NaDONA_Conc</attrlabl>
        <attrdef>Sodium dodecafluoro-3H-4, 8-dioxanonanoate concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.1</rdommin>
            <rdommax>1.5</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>NaDONA_QA</attrlabl>
        <attrdef>Quality assurance check for sodium dodecafluoro-3H-4, 8-dioxanonanoate. 
Concentrations with a qualifier will have one or more letter codes in this field. Absence of qualifiers is also noted.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Associated concentration is less than the LOD and reported as the LOD.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>J</edomv>
            <edomvd>Associated concentration is less than the LOQ; The analyte was positively identified, and the concentrations was estimated as the LOQ divided by 2.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Not applicable; No corresponding qualifiers associated with the concentration.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>NaDONA_SD</attrlabl>
        <attrdef>Sodium dodecafluoro-3H-4, 8-dioxanonanoate standard deviation of lab replicate concentrations expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-</rdommin>
            <rdommax>0.1</rdommax>
            <attrunit>Calculated standard deviation value.</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFHpS_Conc</attrlabl>
        <attrdef>Perfluoroheptane sulfonic acid concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.1</rdommin>
            <rdommax>16.6</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFHpS_QA</attrlabl>
        <attrdef>Quality assurance check for perfluoroheptane sulfonic acid. 
Concentrations with a qualifier will have one or more letter codes in this field. Absence of qualifiers is also noted.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Associated concentration is less than the LOD and reported as the LOD.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Not applicable; No corresponding qualifiers associated with the concentration.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>J</edomv>
            <edomvd>Associated concentration is less than the LOQ; The analyte was positively identified, and the concentrations was estimated as the LOQ divided by 2.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFHpS_SD</attrlabl>
        <attrdef>Perfluoroheptane sulfonic acid standard deviation of lab replicate concentrations expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-</rdommin>
            <rdommax>2</rdommax>
            <attrunit>Calculated standard deviation value.</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFOA_Conc</attrlabl>
        <attrdef>Perfluorooctanoic acid concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.1</rdommin>
            <rdommax>20.7</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFOA_QA</attrlabl>
        <attrdef>Quality assurance check for perfluorooctanoic acid. 
Concentrations with a qualifier will have one or more letter codes in this field. Absence of qualifiers is also noted.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Associated concentration is less than the LOD and reported as the LOD.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Not applicable; No corresponding qualifiers associated with the concentration.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>J</edomv>
            <edomvd>Associated concentration is less than the LOQ; The analyte was positively identified, and the concentrations was estimated as the LOQ divided by 2.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFOA_SD</attrlabl>
        <attrdef>Perfluorooctanoic acid standard deviation of lab replicate concentrations expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-</rdommin>
            <rdommax>2.8</rdommax>
            <attrunit>Calculated standard deviation value.</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>6_2FTS_Conc</attrlabl>
        <attrdef>1H,1H,2H,2H-perfluorooctane sulfonic acid concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.2</rdommin>
            <rdommax>13.7</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>6_2FTS_QA</attrlabl>
        <attrdef>Quality assurance check for 1H,1H,2H,2H-perfluorooctane sulfonic acid. 
Concentrations with a qualifier will have one or more letter codes in this field. Absence of qualifiers is also noted.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Associated concentration is less than the LOD and reported as the LOD.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>J</edomv>
            <edomvd>Associated concentration is less than the LOQ; The analyte was positively identified, and the concentrations was estimated as the LOQ divided by 2.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Not applicable; No corresponding qualifiers associated with the concentration.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>6_2FTS_SD</attrlabl>
        <attrdef>1H,1H,2H,2H-perfluorooctane sulfonic acid standard deviation of lab replicate concentrations expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-</rdommin>
            <rdommax>3.7</rdommax>
            <attrunit>Calculated standard deviation value.</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFOS_Conc</attrlabl>
        <attrdef>Perfluorooctane sulfonic acid concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.3</rdommin>
            <rdommax>112.5</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFOS_QA</attrlabl>
        <attrdef>Quality assurance check for perfluorooctane sulfonic acid. 
Concentrations with a qualifier will have one or more letter codes in this field. Absence of qualifiers is also noted.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Associated concentration is less than the LOD and reported as the LOD.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>J</edomv>
            <edomvd>Associated concentration is less than the LOQ; The analyte was positively identified, and the concentrations was estimated as the LOQ divided by 2.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Not applicable; No corresponding qualifiers associated with the concentration.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFOS_SD</attrlabl>
        <attrdef>Perfluorooctane sulfonic acid standard deviation of lab replicate concentrations expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-</rdommin>
            <rdommax>79.5</rdommax>
            <attrunit>Calculated standard deviation value.</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFNA_Conc</attrlabl>
        <attrdef>Perfluorononanoic acid concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.2</rdommin>
            <rdommax>5.3</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFNA_QA</attrlabl>
        <attrdef>Quality assurance check for perfluorononanoic acid. 
Concentrations with a qualifier will have one or more letter codes in this field. Absence of qualifiers is also noted.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Associated concentration is less than the LOD and reported as the LOD.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>J</edomv>
            <edomvd>Associated concentration is less than the LOQ; The analyte was positively identified, and the concentrations was estimated as the LOQ divided by 2.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Not applicable; No corresponding qualifiers associated with the concentration.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFNA_SD</attrlabl>
        <attrdef>Perfluorononanoic acid standard deviation of lab replicate concentrations expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-</rdommin>
            <rdommax>1.2</rdommax>
            <attrunit>Calculated standard deviation value.</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>9Cl_PF3ONS_Conc</attrlabl>
        <attrdef>9-chlorohexadecafluoro-3-oxanonane-1-sulfonic acid concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.1</rdommin>
            <rdommax>4.0</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>9Cl_PF3ONS_QA</attrlabl>
        <attrdef>Quality assurance check for 9-chlorohexadecafluoro-3-oxanonane-1-sulfonic acid. 
Concentrations with a qualifier will have one or more letter codes in this field. Absence of qualifiers is also noted.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Associated concentration is less than the LOD and reported as the LOD.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>J</edomv>
            <edomvd>Associated concentration is less than the LOQ; The analyte was positively identified, and the concentrations was estimated as the LOQ divided by 2.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>9Cl_PF3ONS_SD</attrlabl>
        <attrdef>9-chlorohexadecafluoro-3-oxanonane-1-sulfonic acid standard deviation of lab replicate concentrations expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-</rdommin>
            <rdommax>-</rdommax>
            <attrunit>Calculated standard deviation value.</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFNS_Conc</attrlabl>
        <attrdef>Perfluorononane sulfonic acid concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.2</rdommin>
            <rdommax>11.1</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFNS_QA</attrlabl>
        <attrdef>Quality assurance check for perfluorononane sulfonic acid. 
Concentrations with a qualifier will have one or more letter codes in this field. Absence of qualifiers is also noted.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Associated concentration is less than the LOD and reported as the LOD.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>J</edomv>
            <edomvd>Associated concentration is less than the LOQ; The analyte was positively identified, and the concentrations was estimated as the LOQ divided by 2.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFNS_SD</attrlabl>
        <attrdef>Perfluorononane sulfonic acid standard deviation of lab replicate concentrations expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-</rdommin>
            <rdommax>-</rdommax>
            <attrunit>Calculated standard deviation value.</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFDA_Conc</attrlabl>
        <attrdef>Perfluorodecanoic acid concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.1</rdommin>
            <rdommax>21.2</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFDA_QA</attrlabl>
        <attrdef>Quality assurance check for perfluorodecanoic acid. 
Concentrations with a qualifier will have one or more letter codes in this field. Absence of qualifiers is also noted.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Associated concentration is less than the LOD and reported as the LOD.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>J</edomv>
            <edomvd>Associated concentration is less than the LOQ; The analyte was positively identified, and the concentrations was estimated as the LOQ divided by 2.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Not applicable; No corresponding qualifiers associated with the concentration.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFDA_SD</attrlabl>
        <attrdef>Perfluorodecanoic acid standard deviation of lab replicate concentrations expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-</rdommin>
            <rdommax>3.3</rdommax>
            <attrunit>Calculated standard deviation value.</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>8_2FTS_Conc</attrlabl>
        <attrdef>1H, 1H, 2H, 2H-perfluorodecane sulfonic acid concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.2</rdommin>
            <rdommax>8.9</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>8_2FTS_QA</attrlabl>
        <attrdef>Quality assurance check for 1H, 1H, 2H, 2H-perfluorodecane sulfonic acid. 
Concentrations with a qualifier will have one or more letter codes in this field. Absence of qualifiers is also noted.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Associated concentration is less than the LOD and reported as the LOD.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>J</edomv>
            <edomvd>Associated concentration is less than the LOQ; The analyte was positively identified, and the concentrations was estimated as the LOQ divided by 2.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Not applicable; No corresponding qualifiers associated with the concentration.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>8_2FTS_SD</attrlabl>
        <attrdef>1H, 1H, 2H, 2H-perfluorodecane sulfonic acid standard deviation of lab replicate concentrations expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-</rdommin>
            <rdommax>2</rdommax>
            <attrunit>Calculated standard deviation value.</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>N_MeFOSAA_Conc</attrlabl>
        <attrdef>N-methyl perfluorooctanesulfonamidoacetic acid concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.2</rdommin>
            <rdommax>42.6</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>N_MeFOSAA_QA</attrlabl>
        <attrdef>Quality assurance check for N-methyl perfluorooctanesulfonamidoacetic acid. 
Concentrations with a qualifier will have one or more letter codes in this field. Absence of qualifiers is also noted.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Associated concentration is less than the LOD and reported as the LOD.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>J</edomv>
            <edomvd>Associated concentration is less than the LOQ; The analyte was positively identified, and the concentrations was estimated as the LOQ divided by 2.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Not applicable; No corresponding qualifiers associated with the concentration.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>N_MeFOSAA_SD</attrlabl>
        <attrdef>N-methyl perfluorooctanesulfonamidoacetic acid standard deviation of lab replicate concentrations expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-</rdommin>
            <rdommax>56</rdommax>
            <attrunit>Calculated standard deviation value.</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFDS_Conc</attrlabl>
        <attrdef>Perfluorodecane sulfonic acid concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.2</rdommin>
            <rdommax>24.0</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFDS_QA</attrlabl>
        <attrdef>Quality assurance check for perfluorodecane sulfonic acid. 
Concentrations with a qualifier will have one or more letter codes in this field. Absence of qualifiers is also noted.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Associated concentration is less than the LOD and reported as the LOD.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>J</edomv>
            <edomvd>Associated concentration is less than the LOQ; The analyte was positively identified, and the concentrations was estimated as the LOQ divided by 2.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Not applicable; No corresponding qualifiers associated with the concentration.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFDS_SD</attrlabl>
        <attrdef>Perfluorodecane sulfonic acid standard deviation of lab replicate concentrations expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-</rdommin>
            <rdommax>4.5</rdommax>
            <attrunit>Calculated standard deviation value.</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFUdA_Conc</attrlabl>
        <attrdef>Perfluoroundecanoic acid concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.1</rdommin>
            <rdommax>28.7</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFUdA_QA</attrlabl>
        <attrdef>Quality assurance check for perfluoroundecanoic acid. 
Concentrations with a qualifier will have one or more letter codes in this field. Absence of qualifiers is also noted.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Associated concentration is less than the LOD and reported as the LOD.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>J</edomv>
            <edomvd>Associated concentration is less than the LOQ; The analyte was positively identified, and the concentrations was estimated as the LOQ divided by 2.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Not applicable; No corresponding qualifiers associated with the concentration.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFUdA_SD</attrlabl>
        <attrdef>Perfluoroundecanoic acid standard deviation of lab replicate concentrations expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-</rdommin>
            <rdommax>6.2</rdommax>
            <attrunit>Calculated standard deviation value.</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>N_EtFOSAA_Conc</attrlabl>
        <attrdef>N-ethyl perfluorooctanesulfonamidoacetic acid concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.1</rdommin>
            <rdommax>81.1</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>N_EtFOSAA_QA</attrlabl>
        <attrdef>Quality assurance check for N-ethyl perfluorooctanesulfonamidoacetic acid. 
Concentrations with a qualifier will have one or more letter codes in this field. Absence of qualifiers is also noted.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Associated concentration is less than the LOD and reported as the LOD.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Not applicable; No corresponding qualifiers associated with the concentration.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>J</edomv>
            <edomvd>Associated concentration is less than the LOQ; The analyte was positively identified, and the concentrations was estimated as the LOQ divided by 2.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>N_EtFOSAA_SD</attrlabl>
        <attrdef>N-ethyl perfluorooctanesulfonamidoacetic acid standard deviation of lab replicate concentrations expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-</rdommin>
            <rdommax>17.9</rdommax>
            <attrunit>Calculated standard deviation value.</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFOSA_Conc</attrlabl>
        <attrdef>Perfluorooctanesulfonamide concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.5</rdommin>
            <rdommax>75.0</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFOSA_QA</attrlabl>
        <attrdef>Quality assurance check for perfluorooctanesulfonamide. 
Concentrations with a qualifier will have one or more letter codes in this field. Absence of qualifiers is also noted.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Associated concentration is less than the LOD and reported as the LOD.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>J</edomv>
            <edomvd>Associated concentration is less than the LOQ; The analyte was positively identified, and the concentrations was estimated as the LOQ divided by 2.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>UB</edomv>
            <edomvd>Associated concentration is less than the LOD and reported as the LOD.
Compound present in lab, trip, or equipment blank; Blank is above the LOD.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>JB</edomv>
            <edomvd>Associated concentration is less than the LOQ; The analyte was positively identified, and the concentrations was estimated as the LOQ divided by 2. Compound present in lab, trip, or equipment blank; Blank is above the LOD.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFOSA_SD</attrlabl>
        <attrdef>Perfluorooctanesulfonamide standard deviation of lab replicate concentrations expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-</rdommin>
            <rdommax>-</rdommax>
            <attrunit>Calculated standard deviation value.</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>11Cl_PF3OUdS_Conc</attrlabl>
        <attrdef>11-chloroeicosafluoro-3-oxaundecane-1-sulfonic acid concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.2</rdommin>
            <rdommax>8.1</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>11Cl_PF3OUdS_QA</attrlabl>
        <attrdef>Quality assurance check for 11-chloroeicosafluoro-3-oxaundecane-1-sulfonic acid. 
Concentrations with a qualifier will have one or more letter codes in this field. Absence of qualifiers is also noted.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Associated concentration is less than the LOD and reported as the LOD.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>11Cl_PF3OUdS_SD</attrlabl>
        <attrdef>11-chloroeicosafluoro-3-oxaundecane-1-sulfonic acid standard deviation of lab replicate concentrations expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-</rdommin>
            <rdommax>-</rdommax>
            <attrunit>Calculated standard deviation value.</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFDoA_Conc</attrlabl>
        <attrdef>Perfluorododecanoic acid concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.4</rdommin>
            <rdommax>21.5</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFDoA_QA</attrlabl>
        <attrdef>Quality assurance check for perfluorododecanoic acid. Concentrations with a qualifier will have one or more letter codes in this field. Absence of qualifiers is also noted.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Associated concentration is less than the LOD and reported as the LOD.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>J</edomv>
            <edomvd>Associated concentration is less than the LOQ; The analyte was positively identified, and the concentrations was estimated as the LOQ divided by 2.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Not applicable; No corresponding qualifiers associated with the concentration.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFDoA_SD</attrlabl>
        <attrdef>Perfluorododecanoic acid standard deviation of lab replicate concentrations expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-</rdommin>
            <rdommax>2.6</rdommax>
            <attrunit>Calculated standard deviation value.</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFTrDA_Conc</attrlabl>
        <attrdef>Perfluorotridecanoic acid concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.4</rdommin>
            <rdommax>15.3</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFTrDA_QA</attrlabl>
        <attrdef>Quality assurance check for perfluorotridecanoic acid. 
Concentrations with a qualifier will have one or more letter codes in this field. Absence of qualifiers is also noted.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Associated concentration is less than the LOD and reported as the LOD.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>J</edomv>
            <edomvd>Associated concentration is less than the LOQ; The analyte was positively identified, and the concentrations was estimated as the LOQ divided by 2.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Not applicable; No corresponding qualifiers associated with the concentration.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFTrDA_SD</attrlabl>
        <attrdef>Perfluorotridecanoic acid standard deviation of lab replicate concentrations expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-</rdommin>
            <rdommax>5.2</rdommax>
            <attrunit>Calculated standard deviation value.</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFTeDA_Conc</attrlabl>
        <attrdef>Perfluorotetradecanoic acid concentration expressed in nanograms per gram of dry weight.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.5</rdommin>
            <rdommax>28.3</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFTeDA_QA</attrlabl>
        <attrdef>Quality assurance check for perfluorotetradecanoic acid. Concentrations with a qualifier will have one or more letter codes in this field. Absence of qualifiers is also noted.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Associated concentration is less than the LOD and reported as the LOD.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>J</edomv>
            <edomvd>Associated concentration is less than the LOQ; The analyte was positively identified, and the concentrations was estimated as the LOQ divided by 2.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFTeDA_SD</attrlabl>
        <attrdef>Perfluorotetradecanoic acid standard deviation of lab replicate concentrations expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-</rdommin>
            <rdommax>-</rdommax>
            <attrunit>Calculated standard deviation value.</attrunit>
          </rdom>
        </attrdomv>
      </attr>
    </detailed>
    <detailed>
      <enttyp>
        <enttypl>PatapscoWWTP_TOP_Data.csv</enttypl>
        <enttypd>Comma Separated Value (CSV) file containing PFAS concentrations by total oxidizable precursor (TOP) assay analysis and associated quality control information in aqueous influent and effluent and biosolids collected from wastewater treatment plants within the Patapsco watershed, March, and September 2022.</enttypd>
        <enttypds>UMBC Defined</enttypds>
      </enttyp>
      <attr>
        <attrlabl>Sample_ID</attrlabl>
        <attrdef>USGS generated unique sample identifier.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <udom>Each sample was given a unique sequential number by the USGS that corresponds with the sample name for each specific site.</udom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Sample_Name</attrlabl>
        <attrdef>Origin of wastewater or biosolid samples.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <udom>Each site was given a unique name identifier.</udom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Collection_Date</attrlabl>
        <attrdef>Date when the sample was collected from the site.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>3/22/2022</rdommin>
            <rdommax>9/22/2022</rdommax>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Watershed</attrlabl>
        <attrdef>Watershed in which the site is located.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>Patapsco</edomv>
            <edomvd>Affected watershed</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Sample_Type</attrlabl>
        <attrdef>Sample source type</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>Effluent</edomv>
            <edomvd>Water discharged into a waterway after the wastewater treatment process.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>Influent</edomv>
            <edomvd>Untreated wastewater or raw sewage entering the wastewater treatment plant.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>Biosolids</edomv>
            <edomvd>Dewatered and treated solid residuals of the wastewater treatment plant.</edomvd>
            <edomvds>USGS Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>Concentration_Units</attrlabl>
        <attrdef>PFAS compound concentration units are in nanograms per gram of dry weight for biosolids (BS) samples and nanograms per liter for aqueous (AQ) samples.</attrdef>
        <attrdefs>USGS Defined</attrdefs>
        <attrdomv>
          <udom>PFAS concentration units are in nanograms per gram of dry weight for biosolids (BS) samples and nanograms per liter for aqueous (AQ) samples.</udom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFBA_Conc</attrlabl>
        <attrdef>Perfluorobutanoic acid concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>1.6</rdommin>
            <rdommax>36.5</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFBA_QA</attrlabl>
        <attrdef>Quality assurance check for perfluorobutanoic acid. 
Concentrations with a qualifier will have one or more letter codes in this field. Absence of qualifiers is also noted.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Not applicable; No corresponding qualifiers associated with the concentration.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>J</edomv>
            <edomvd>Associated concentration is less than the LOQ; The analyte was positively identified, and the concentrations was estimated as the LOQ divided by 2.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Associated concentration is less than the LOD and reported as the LOD.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFBA_SD</attrlabl>
        <attrdef>Perfluorobutanoic acid standard deviation of lab replicate concentrations expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-</rdommin>
            <rdommax>8.2</rdommax>
            <attrunit>Calculated standard deviation value.</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFPeA_Conc</attrlabl>
        <attrdef>Perfluoropentanoic acid concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>1.6</rdommin>
            <rdommax>71.8</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFPeA_QA</attrlabl>
        <attrdef>Quality assurance check for perfluoropentanoic acid. 
Concentrations with a qualifier will have one or more letter codes in this field. Absence of qualifiers is also noted.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Not applicable; No corresponding qualifiers associated with the concentration.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>J</edomv>
            <edomvd>Associated concentration is less than the LOQ; The analyte was positively identified, and the concentrations was estimated as the LOQ divided by 2.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Associated concentration is less than the LOD and reported as the LOD.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFPeA_SD</attrlabl>
        <attrdef>Perfluoropentanoic acid standard deviation of lab replicate concentrations expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-</rdommin>
            <rdommax>6.9</rdommax>
            <attrunit>Calculated standard deviation value.</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFBS_Conc</attrlabl>
        <attrdef>Perfluorobutane sulfonic acid concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.1</rdommin>
            <rdommax>10.5</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFBS_QA</attrlabl>
        <attrdef>Quality assurance check for perfluorobutane sulfonic acid. Concentrations with a qualifier will have one or more letter codes in this field. Absence of qualifiers is also noted.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Not applicable; No corresponding qualifiers associated with the concentration.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Associated concentration is less than the LOD and reported as the LOD.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>J</edomv>
            <edomvd>Associated concentration is less than the LOQ; The analyte was positively identified, and the concentrations was estimated as the LOQ divided by 2.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFBS_SD</attrlabl>
        <attrdef>Perfluorobutane sulfonic acid standard deviation of lab replicate concentrations expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-</rdommin>
            <rdommax>5.5</rdommax>
            <attrunit>Calculated standard deviation value.</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>4_2FTS_Conc</attrlabl>
        <attrdef>1H, 1H, 2H, 2H-perfluorohexane sulfonic acid concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.3</rdommin>
            <rdommax>16.2</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>4_2FTS_QA</attrlabl>
        <attrdef>Quality assurance check for 1H, 1H, 2H, 2H-perfluorohexane sulfonic acid. 
Concentrations with a qualifier will have one or more letter codes in this field. Absence of qualifiers is also noted.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>J</edomv>
            <edomvd>Associated concentration is less than the LOQ; The analyte was positively identified, and the concentrations was estimated as the LOQ divided by 2.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Associated concentration is less than the LOD and reported as the LOD.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Not applicable; No corresponding qualifiers associated with the concentration.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>4_2FTS_SD</attrlabl>
        <attrdef>1H, 1H, 2H, 2H-perfluorohexane sulfonic acid standard deviation of lab replicate concentrations expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-</rdommin>
            <rdommax>3.8</rdommax>
            <attrunit>Calculated standard deviation value.</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFHxA_Conc</attrlabl>
        <attrdef>Perfluorohexanoic acid concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>1.2</rdommin>
            <rdommax>53.6</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFHxA_QA</attrlabl>
        <attrdef>Quality assurance check for perfluorohexanoic acid. 
Concentrations with a qualifier will have one or more letter codes in this field. Absence of qualifiers is also noted.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Not applicable; No corresponding qualifiers associated with the concentration.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>J</edomv>
            <edomvd>Associated concentration is less than the LOQ; The analyte was positively identified, and the concentrations was estimated as the LOQ divided by 2.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFHxA_SD</attrlabl>
        <attrdef>Perfluorohexanoic acid standard deviation of lab replicate concentrations expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-</rdommin>
            <rdommax>6.4</rdommax>
            <attrunit>Calculated standard deviation value.</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFPeS_Conc</attrlabl>
        <attrdef>Perfluropentane sulfonic acid concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.6</rdommin>
            <rdommax>13.0</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFPeS_QA</attrlabl>
        <attrdef>Quality assurance check for perfluropentane sulfonic acid. 
Concentrations with a qualifier will have one or more letter codes in this field. Absence of qualifiers is also noted.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>J</edomv>
            <edomvd>Associated concentration is less than the LOQ; The analyte was positively identified, and the concentrations was estimated as the LOQ divided by 2.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Associated concentration is less than the LOD and reported as the LOD.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Not applicable; No corresponding qualifiers associated with the concentration.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFPeS_SD</attrlabl>
        <attrdef>Perfluropentane sulfonic acid standard deviation of lab replicate concentrations expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-</rdommin>
            <rdommax>3.7</rdommax>
            <attrunit>Calculated standard deviation value.</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>HFPO_DA_Conc</attrlabl>
        <attrdef>Hexafluoropropylene oxide dimer acid concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>1.0</rdommin>
            <rdommax>3.1</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>HFPO_DA_QA</attrlabl>
        <attrdef>Quality assurance check for hexafluoropropylene oxide dimer acid. 
Concentrations with a qualifier will have one or more letter codes in this field. Absence of qualifiers is also noted.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Associated concentration is less than the LOD and reported as the LOD.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>J</edomv>
            <edomvd>Associated concentration is less than the LOQ; The analyte was positively identified, and the concentrations was estimated as the LOQ divided by 2.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>HFPO_DA_SD</attrlabl>
        <attrdef>Hexafluoropropylene oxide dimer acid standard deviation of lab replicate concentrations expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-</rdommin>
            <rdommax>-</rdommax>
            <attrunit>Calculated standard deviation value.</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFHpA_Conc</attrlabl>
        <attrdef>Perfluoroheptanoic acid concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>2.4</rdommin>
            <rdommax>24.5</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFHpA_QA</attrlabl>
        <attrdef>Quality assurance check for perfluoroheptanoic acid. 
Concentrations with a qualifier will have one or more letter codes in this field. Absence of qualifiers is also noted.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Not applicable; No corresponding qualifiers associated with the concentration.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Associated concentration is less than the LOD and reported as the LOD.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>J</edomv>
            <edomvd>Associated concentration is less than the LOQ; The analyte was positively identified, and the concentrations was estimated as the LOQ divided by 2.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFHpA_SD</attrlabl>
        <attrdef>Perfluoroheptanoic acid standard deviation of lab replicate concentrations expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-</rdommin>
            <rdommax>5</rdommax>
            <attrunit>Calculated standard deviation value.</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFHxS_Conc</attrlabl>
        <attrdef>Perfluorohexane sulfonic acid concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.3</rdommin>
            <rdommax>12.2</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFHxS_QA</attrlabl>
        <attrdef>Quality assurance check for perfluorohexane sulfonic acid. 
Concentrations with a qualifier will have one or more letter codes in this field. Absence of qualifiers is also noted.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Not applicable; No corresponding qualifiers associated with the concentration.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>J</edomv>
            <edomvd>Associated concentration is less than the LOQ; The analyte was positively identified, and the concentrations was estimated as the LOQ divided by 2.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Associated concentration is less than the LOD and reported as the LOD.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFHxS_SD</attrlabl>
        <attrdef>Perfluorohexane sulfonic acid standard deviation of lab replicate concentrations expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-</rdommin>
            <rdommax>8.7</rdommax>
            <attrunit>Calculated standard deviation value.</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>NaDONA_Conc</attrlabl>
        <attrdef>Sodium dodecafluoro-3H-4, 8-dioxanonanoate concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.2</rdommin>
            <rdommax>1.2</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>NaDONA_QA</attrlabl>
        <attrdef>Quality assurance check for sodium dodecafluoro-3H-4, 8-dioxanonanoate. 
Concentrations with a qualifier will have one or more letter codes in this field. Absence of qualifiers is also noted.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Associated concentration is less than the LOD and reported as the LOD.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>J</edomv>
            <edomvd>Associated concentration is less than the LOQ; The analyte was positively identified, and the concentrations was estimated as the LOQ divided by 2.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>NaDONA_SD</attrlabl>
        <attrdef>Sodium dodecafluoro-3H-4, 8-dioxanonanoate standard deviation of lab replicate concentrations expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-</rdommin>
            <rdommax>-</rdommax>
            <attrunit>Calculated standard deviation value.</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFHpS_Conc</attrlabl>
        <attrdef>Perfluoroheptane sulfonic acid concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.6</rdommin>
            <rdommax>2.5</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFHpS_QA</attrlabl>
        <attrdef>Quality assurance check for perfluoroheptane sulfonic acid. 
Concentrations with a qualifier will have one or more letter codes in this field. Absence of qualifiers is also noted.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>J</edomv>
            <edomvd>Associated concentration is less than the LOQ; The analyte was positively identified, and the concentrations was estimated as the LOQ divided by 2.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Associated concentration is less than the LOD and reported as the LOD.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFHpS_SD</attrlabl>
        <attrdef>Perfluoroheptane sulfonic acid standard deviation of lab replicate concentrations expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-</rdommin>
            <rdommax>-</rdommax>
            <attrunit>Calculated standard deviation value.</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFOA_Conc</attrlabl>
        <attrdef>Perfluorooctanoic acid concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.7</rdommin>
            <rdommax>23.7</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFOA_QA</attrlabl>
        <attrdef>Quality assurance check for perfluorooctanoic acid. 
Concentrations with a qualifier will have one or more letter codes in this field. Absence of qualifiers is also noted.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Not applicable; No corresponding qualifiers associated with the concentration.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>J</edomv>
            <edomvd>Associated concentration is less than the LOQ; The analyte was positively identified, and the concentrations was estimated as the LOQ divided by 2.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFOA_SD</attrlabl>
        <attrdef>Perfluorooctanoic acid standard deviation of lab replicate concentrations expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-</rdommin>
            <rdommax>3.8</rdommax>
            <attrunit>Calculated standard deviation value.</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>6_2FTS_Conc</attrlabl>
        <attrdef>1H,1H,2H,2H-perfluorooctane sulfonic acid concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.2</rdommin>
            <rdommax>6.4</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>6_2FTS_QA</attrlabl>
        <attrdef>Quality assurance check for 1H,1H,2H,2H-perfluorooctane sulfonic acid. 
Concentrations with a qualifier will have one or more letter codes in this field. Absence of qualifiers is also noted.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Associated concentration is less than the LOD and reported as the LOD.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>J</edomv>
            <edomvd>Associated concentration is less than the LOQ; The analyte was positively identified, and the concentrations was estimated as the LOQ divided by 2.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Not applicable; No corresponding qualifiers associated with the concentration.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>6_2FTS_SD</attrlabl>
        <attrdef>1H,1H,2H,2H-perfluorooctane sulfonic acid standard deviation of lab replicate concentrations expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-</rdommin>
            <rdommax>2.4</rdommax>
            <attrunit>Calculated standard deviation value.</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFOS_Conc</attrlabl>
        <attrdef>Perfluorooctane sulfonic acid concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>2.5</rdommin>
            <rdommax>43.0</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFOS_QA</attrlabl>
        <attrdef>Quality assurance check for perfluorooctane sulfonic acid. 
Concentrations with a qualifier will have one or more letter codes in this field. Absence of qualifiers is also noted.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Not applicable; No corresponding qualifiers associated with the concentration.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>J</edomv>
            <edomvd>Associated concentration is less than the LOQ; The analyte was positively identified, and the concentrations was estimated as the LOQ divided by 2.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFOS_SD</attrlabl>
        <attrdef>Perfluorooctane sulfonic acid standard deviation of lab replicate concentrations expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-</rdommin>
            <rdommax>8.2</rdommax>
            <attrunit>Calculated standard deviation value.</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFNA_Conc</attrlabl>
        <attrdef>Perfluorononanoic acid concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>1.1</rdommin>
            <rdommax>5.1</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFNA_QA</attrlabl>
        <attrdef>Quality assurance check for perfluorononanoic acid. 
Concentrations with a qualifier will have one or more letter codes in this field. Absence of qualifiers is also noted.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>J</edomv>
            <edomvd>Associated concentration is less than the LOQ; The analyte was positively identified, and the concentrations was estimated as the LOQ divided by 2.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Associated concentration is less than the LOD and reported as the LOD.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Not applicable; No corresponding qualifiers associated with the concentration.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFNA_SD</attrlabl>
        <attrdef>Perfluorononanoic acid standard deviation of lab replicate concentrations expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-</rdommin>
            <rdommax>2</rdommax>
            <attrunit>Calculated standard deviation value.</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>9Cl_PF3ONS_Conc</attrlabl>
        <attrdef>9-chlorohexadecafluoro-3-oxanonane-1-sulfonic acid concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.6</rdommin>
            <rdommax>4.1</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>9Cl_PF3ONS_QA</attrlabl>
        <attrdef>Quality assurance check for 9-chlorohexadecafluoro-3-oxanonane-1-sulfonic acid. 
Concentrations with a qualifier will have one or more letter codes in this field. Absence of qualifiers is also noted.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Associated concentration is less than the LOD and reported as the LOD.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>9Cl_PF3ONS_SD</attrlabl>
        <attrdef>9-chlorohexadecafluoro-3-oxanonane-1-sulfonic acid standard deviation of lab replicate concentrations expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-</rdommin>
            <rdommax>-</rdommax>
            <attrunit>Calculated standard deviation value.</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFNS_Conc</attrlabl>
        <attrdef>Perfluorononane sulfonic acid concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.6</rdommin>
            <rdommax>1.5</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFNS_QA</attrlabl>
        <attrdef>Quality assurance check for perfluorononane sulfonic acid. 
Concentrations with a qualifier will have one or more letter codes in this field. Absence of qualifiers is also noted.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Associated concentration is less than the LOD and reported as the LOD.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>J</edomv>
            <edomvd>Associated concentration is less than the LOQ; The analyte was positively identified, and the concentrations was estimated as the LOQ divided by 2.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFNS_SD</attrlabl>
        <attrdef>Perfluorononane sulfonic acid standard deviation of lab replicate concentrations expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-</rdommin>
            <rdommax>-</rdommax>
            <attrunit>Calculated standard deviation value.</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFDA_Conc</attrlabl>
        <attrdef>Perfluorodecanoic acid concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>2.3</rdommin>
            <rdommax>20.8</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFDA_QA</attrlabl>
        <attrdef>Quality assurance check for perfluorodecanoic acid. 
Concentrations with a qualifier will have one or more letter codes in this field. Absence of qualifiers is also noted.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Associated concentration is less than the LOD and reported as the LOD.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Not applicable; No corresponding qualifiers associated with the concentration.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>J</edomv>
            <edomvd>Associated concentration is less than the LOQ; The analyte was positively identified, and the concentrations was estimated as the LOQ divided by 2.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFDA_SD</attrlabl>
        <attrdef>Perfluorodecanoic acid standard deviation of lab replicate concentrations expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-</rdommin>
            <rdommax>3.5</rdommax>
            <attrunit>Calculated standard deviation value.</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>8_2FTS_Conc</attrlabl>
        <attrdef>1H, 1H, 2H, 2H-perfluorodecane sulfonic acid concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>2.1</rdommin>
            <rdommax>7.7</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>8_2FTS_QA</attrlabl>
        <attrdef>Quality assurance check for 1H, 1H, 2H, 2H-perfluorodecane sulfonic acid. 
Concentrations with a qualifier will have one or more letter codes in this field. Absence of qualifiers is also noted.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Associated concentration is less than the LOD and reported as the LOD.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>8_2FTS_SD</attrlabl>
        <attrdef>1H, 1H, 2H, 2H-perfluorodecane sulfonic acid standard deviation of lab replicate concentrations expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-</rdommin>
            <rdommax>-</rdommax>
            <attrunit>Calculated standard deviation value.</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>N_MeFOSAA_Conc</attrlabl>
        <attrdef>N-methyl perfluorooctanesulfonamidoacetic acid concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>2.0</rdommin>
            <rdommax>2.2</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>N_MeFOSAA_QA</attrlabl>
        <attrdef>Quality assurance check for N-methyl perfluorooctanesulfonamidoacetic acid. 
Concentrations with a qualifier will have one or more letter codes in this field. Absence of qualifiers is also noted.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Associated concentration is less than the LOD and reported as the LOD.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>N_MeFOSAA_SD</attrlabl>
        <attrdef>N-methyl perfluorooctanesulfonamidoacetic acid standard deviation of lab replicate concentrations expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-</rdommin>
            <rdommax>-</rdommax>
            <attrunit>Calculated standard deviation value.</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFDS_Conc</attrlabl>
        <attrdef>Perfluorodecane sulfonic acid concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.6</rdommin>
            <rdommax>1.5</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFDS_QA</attrlabl>
        <attrdef>Quality assurance check for perfluorodecane sulfonic acid. 
Concentrations with a qualifier will have one or more letter codes in this field. Absence of qualifiers is also noted.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Associated concentration is less than the LOD and reported as the LOD.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>J</edomv>
            <edomvd>Associated concentration is less than the LOQ; The analyte was positively identified, and the concentrations was estimated as the LOQ divided by 2.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFDS_SD</attrlabl>
        <attrdef>Perfluorodecane sulfonic acid standard deviation of lab replicate concentrations expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-</rdommin>
            <rdommax>-</rdommax>
            <attrunit>Calculated standard deviation value.</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFUdA_Conc</attrlabl>
        <attrdef>Perfluoroundecanoic acid concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>1.2</rdommin>
            <rdommax>7.0</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFUdA_QA</attrlabl>
        <attrdef>Quality assurance check for perfluoroundecanoic acid. 
Concentrations with a qualifier will have one or more letter codes in this field. Absence of qualifiers is also noted.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Associated concentration is less than the LOD and reported as the LOD.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Not applicable; No corresponding qualifiers associated with the concentration.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>J</edomv>
            <edomvd>Associated concentration is less than the LOQ; The analyte was positively identified, and the concentrations was estimated as the LOQ divided by 2.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFUdA_SD</attrlabl>
        <attrdef>Perfluoroundecanoic acid standard deviation of lab replicate concentrations expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-</rdommin>
            <rdommax>3.4</rdommax>
            <attrunit>Calculated standard deviation value.</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>N_EtFOSAA_Conc</attrlabl>
        <attrdef>N-ethyl perfluorooctanesulfonamidoacetic acid concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>2.0</rdommin>
            <rdommax>2.2</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>N_EtFOSAA_QA</attrlabl>
        <attrdef>Quality assurance check for N-ethyl perfluorooctanesulfonamidoacetic acid. 
Concentrations with a qualifier will have one or more letter codes in this field. Absence of qualifiers is also noted.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Associated concentration is less than the LOD and reported as the LOD.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>N_EtFOSAA_SD</attrlabl>
        <attrdef>N-ethyl perfluorooctanesulfonamidoacetic acid standard deviation of lab replicate concentrations expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-</rdommin>
            <rdommax>-</rdommax>
            <attrunit>Calculated standard deviation value.</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFOSA_Conc</attrlabl>
        <attrdef>Perfluorooctanesulfonamide concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.8</rdommin>
            <rdommax>1.0</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFOSA_QA</attrlabl>
        <attrdef>Quality assurance check for perfluorooctanesulfonamide. 
Concentrations with a qualifier will have one or more letter codes in this field. Absence of qualifiers is also noted.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Associated concentration is less than the LOD and reported as the LOD.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFOSA_SD</attrlabl>
        <attrdef>Perfluorooctanesulfonamide standard deviation of lab replicate concentrations expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-</rdommin>
            <rdommax>-</rdommax>
            <attrunit>Calculated standard deviation value.</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>11Cl_PF3OUdS_Conc</attrlabl>
        <attrdef>11-chloroeicosafluoro-3-oxaundecane-1-sulfonic acid concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.7</rdommin>
            <rdommax>4.2</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>11Cl_PF3OUdS_QA</attrlabl>
        <attrdef>Quality assurance check for 11-chloroeicosafluoro-3-oxaundecane-1-sulfonic acid. 
Concentrations with a qualifier will have one or more letter codes in this field. Absence of qualifiers is also noted.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Associated concentration is less than the LOD and reported as the LOD.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>11Cl_PF3OUdS_SD</attrlabl>
        <attrdef>11-chloroeicosafluoro-3-oxaundecane-1-sulfonic acid standard deviation of lab replicate concentrations expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-</rdommin>
            <rdommax>-</rdommax>
            <attrunit>Calculated standard deviation value.</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFDoA_Conc</attrlabl>
        <attrdef>Perfluorododecanoic acid concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.9</rdommin>
            <rdommax>5.5</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFDoA_QA</attrlabl>
        <attrdef>Quality assurance check for perfluorododecanoic acid. Concentrations with a qualifier will have one or more letter codes in this field. Absence of qualifiers is also noted.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Associated concentration is less than the LOD and reported as the LOD.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>J</edomv>
            <edomvd>Associated concentration is less than the LOQ; The analyte was positively identified, and the concentrations was estimated as the LOQ divided by 2.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>-</edomv>
            <edomvd>Not applicable; No corresponding qualifiers associated with the concentration.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFDoA_SD</attrlabl>
        <attrdef>Perfluorododecanoic acid standard deviation of lab replicate concentrations expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-</rdommin>
            <rdommax>1.2</rdommax>
            <attrunit>Calculated standard deviation value.</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFTrDA_Conc</attrlabl>
        <attrdef>Perfluorotridecanoic acid concentration expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.7</rdommin>
            <rdommax>2.1</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFTrDA_QA</attrlabl>
        <attrdef>Quality assurance check for perfluorotridecanoic acid. 
Concentrations with a qualifier will have one or more letter codes in this field. Absence of qualifiers is also noted.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Associated concentration is less than the LOD and reported as the LOD.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>J</edomv>
            <edomvd>Associated concentration is less than the LOQ; The analyte was positively identified, and the concentrations was estimated as the LOQ divided by 2.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFTrDA_SD</attrlabl>
        <attrdef>Perfluorotridecanoic acid standard deviation of lab replicate concentrations expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-</rdommin>
            <rdommax>-</rdommax>
            <attrunit>Calculated standard deviation value.</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFTeDA_Conc</attrlabl>
        <attrdef>Perfluorotetradecanoic acid concentration expressed in nanograms per gram of dry weight.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>0.4</rdommin>
            <rdommax>1.0</rdommax>
            <attrunit>Nanograms per gram of dry weight (BS) or nanograms per liter (AQ).</attrunit>
          </rdom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFTeDA_QA</attrlabl>
        <attrdef>Quality assurance check for perfluorotetradecanoic acid. Concentrations with a qualifier will have one or more letter codes in this field. Absence of qualifiers is also noted.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <edom>
            <edomv>U</edomv>
            <edomvd>Associated concentration is less than the LOD and reported as the LOD.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
        <attrdomv>
          <edom>
            <edomv>J</edomv>
            <edomvd>Associated concentration is less than the LOQ; The analyte was positively identified, and the concentrations was estimated as the LOQ divided by 2.</edomvd>
            <edomvds>UMBC Defined</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PFTeDA_SD</attrlabl>
        <attrdef>Perfluorotetradecanoic acid standard deviation of lab replicate concentrations expressed in nanograms per gram of dry weight or nanograms per liter.</attrdef>
        <attrdefs>UMBC Defined</attrdefs>
        <attrdomv>
          <rdom>
            <rdommin>-</rdommin>
            <rdommax>-</rdommax>
            <attrunit>Calculated standard deviation value.</attrunit>
          </rdom>
        </attrdomv>
      </attr>
    </detailed>
  </eainfo>
  <distinfo>
    <distrib>
      <cntinfo>
        <cntperp>
          <cntper>GS ScienceBase</cntper>
          <cntorg>U.S. Geological Survey</cntorg>
        </cntperp>
        <cntaddr>
          <addrtype>mailing address</addrtype>
          <address>Denver Federal Center, Building 810, Mail Stop 302</address>
          <city>Denver</city>
          <state>CO</state>
          <postal>80225</postal>
          <country>United States</country>
        </cntaddr>
        <cntvoice>1-888-275-8747</cntvoice>
        <cntemail>sciencebase@usgs.gov</cntemail>
      </cntinfo>
    </distrib>
    <distliab>Unless otherwise stated, all data, metadata and related materials are considered to satisfy the quality standards relative to the purpose for which the data were collected. Although these data and associated metadata have been reviewed for accuracy and completeness and approved for release by the U.S. Geological Survey (USGS), no warranty expressed or implied is made regarding the display or utility of the data for other purposes, nor on all computer systems, nor shall the act of distribution constitute any such warranty.</distliab>
    <stdorder>
      <digform>
        <digtinfo>
          <formname>Digital Data</formname>
        </digtinfo>
        <digtopt>
          <onlinopt>
            <computer>
              <networka>
                <networkr>https://doi.org/10.5066/P13WUBAD</networkr>
              </networka>
            </computer>
          </onlinopt>
        </digtopt>
      </digform>
      <fees>None</fees>
    </stdorder>
  </distinfo>
  <metainfo>
    <metd>20250314</metd>
    <metc>
      <cntinfo>
        <cntorgp>
          <cntorg>U.S. Geological Survey, Northeast Region</cntorg>
          <cntper>Sindy Mejia</cntper>
        </cntorgp>
        <cntpos>Physical Scientist</cntpos>
        <cntaddr>
          <addrtype>mailing</addrtype>
          <address>5522 Research Park Drive</address>
          <city>Baltimore</city>
          <state>Maryland</state>
          <postal>21228</postal>
          <country>U.S.</country>
        </cntaddr>
        <cntvoice>410-925-8098</cntvoice>
        <cntemail>smejia@usgs.gov</cntemail>
      </cntinfo>
    </metc>
    <metstdn>FGDC Biological Data Profile of the Content Standard for Digital Geospatial Metadata</metstdn>
    <metstdv>FGDC-STD-001.1-1999</metstdv>
  </metainfo>
</metadata>